摘要 | Co-incinerating sewage sludge in municipal solid waste incinerators (MSWIs) is an up-to-date disposal way with great prospects to market. To verify the environmental safety of this disposal method, a field study was conducted in a MSWI which has achieved PCDD/Fs ultra-low emission. PCDD/F phase partitioning characteristics, congener profiles, and the influence of selective catalytic reduction (SCR) were also investigated. PCDD/F emission levels ranged from 0.0031 to 0.0053 ng I-TEQ/Nm, distinctly lower than the national standard. For tests co-incinerating 5% sludge, PCDD/F emission levels were averagely 32% lower than tests mono-combusting municipal solid waste. The phase partitioning study found that PCDD/Fs enriched in condensed water took a non-negligible proportion of the total concentration in flue gas. The removal efficiency of SCR in tests co-incinerating sludge was averaged at 41.9%. However, in tests without adding sewage sludge, PCDD/F concentrations in flus gas after SCR were increased. It was found that the elevations were mainly attributed to the increase of low-chlorinated PCDF congeners in gas-phase. By inference, memory effect existing in SCR might be responsible for the increase of PCDD/F levels. PCDD to PCDF ratios in most of the sampling points were >1, suggesting that de novo synthesis is not the dominant formation pathway in the studied incinerator. This study verified that co-incinerating sewage sludge in the MSWI would not elevate the emission levels of PCDD/Fs. If all of the yielded municipal waste is incinerated with adding 5% sewage sludge, more than half of sewage sludge can be disposed safely in Shenzhen. |
关键词 | |
相关链接 | [Scopus记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 通讯
|
资助项目 | Shenzhen Peacock Plan[KQTD20160226195840229]
|
WOS研究方向 | Engineering
; Environmental Sciences & Ecology
|
WOS类目 | Engineering, Environmental
; Environmental Sciences
|
WOS记录号 | WOS:000525840000017
|
出版者 | |
EI入藏号 | 20201308338064
|
EI主题词 | Ammonia
; Sludge disposal
; Waste incineration
; Municipal solid waste
; Selective catalytic reduction
|
EI分类号 | Air Pollution Control:451.2
; Municipal and Industrial Wastes; Waste Treatment and Disposal:452
; Sewage Treatment:452.2
; Industrial Wastes Treatment and Disposal:452.4
; Inorganic Compounds:804.2
|
ESI学科分类 | ENGINEERING
|
Scopus记录号 | 2-s2.0-85081995844
|
来源库 | Scopus
|
引用统计 |
被引频次[WOS]:44
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/106078 |
专题 | 工学院_环境科学与工程学院 |
作者单位 | 1.Engineering Research Center for Energy and Environment of Chongqing,College of Materials Science and Engineering,Chongqing University,Chongqing,400044,China 2.School of Environmental Science and Engineering,Guangdong Provincial Key Laboratory of Soil and Groundwater Pollution Control,Southern University of Science and Technology,Shenzhen,518055,China 3.State Key Laboratory of Environmental and Biological Analysis,Department of Chemistry,Hong Kong Baptist University,China 4.Shenzhen Energy Environment,Co.,LTD,Shenzhen,518055,China |
通讯作者单位 | 环境科学与工程学院 |
推荐引用方式 GB/T 7714 |
Zhong,Rigang,Wang,Chen,Zhang,Zuotai,et al. PCDD/F levels and phase distributions in a full-scale municipal solid waste incinerator with co-incinerating sewage sludge[J]. WASTE MANAGEMENT,2020,106:110-119.
|
APA |
Zhong,Rigang,Wang,Chen,Zhang,Zuotai,Liu,Qingcai,&Cai,Zongwei.(2020).PCDD/F levels and phase distributions in a full-scale municipal solid waste incinerator with co-incinerating sewage sludge.WASTE MANAGEMENT,106,110-119.
|
MLA |
Zhong,Rigang,et al."PCDD/F levels and phase distributions in a full-scale municipal solid waste incinerator with co-incinerating sewage sludge".WASTE MANAGEMENT 106(2020):110-119.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论