题名 | Evaluation of visible NIR-I and NIR-II light penetration for photoacoustic imaging in rat organs |
作者 | |
通讯作者 | Xi,Lei |
发表日期 | 2020-03-16
|
DOI | |
发表期刊 | |
ISSN | 1094-4087
|
EISSN | 1094-4087
|
卷号 | 28期号:6页码:9002-9013 |
摘要 | In this study, we evaluate the penetration capability of light in visible, near-infrared-I (NIR-I) and near-infrared-II (NIR-II) optical windows for photoacoustic macroscale imaging inside 9 biological tissues with three typical penetration depths. An acoustic resolution photoacoustic microscopy is designed to guarantee the consistent experiment conditions except excitation wavelength. Experimental results show that short NIR-II (1000-1150 nm) shows the best performance inside kidney, spleen and liver tissues at all depths, while NIR-I (700-1000 nm) works better for muscle, stomach, heart and brain tissues, especially in deep imaging. This study proposes the optimal selection of illumination wavelengths for photoacoustic macroscale imaging in rat organs, which enables the best signal-to-noise ratio (SNR) of the observed target. |
相关链接 | [Scopus记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
; 通讯
|
资助项目 | National Natural Science Foundation of China[61775028]
|
WOS研究方向 | Optics
|
WOS类目 | Optics
|
WOS记录号 | WOS:000522511600102
|
出版者 | |
EI入藏号 | 20201208332390
|
EI主题词 | Photoacoustic effect
; Photoacoustic microscopy
; Signal to noise ratio
; Infrared devices
; Tissue
; Histology
|
EI分类号 | Biological Materials and Tissue Engineering:461.2
; Information Theory and Signal Processing:716.1
; Light/Optics:741.1
; Imaging Techniques:746
; Acoustic Waves:751.1
|
ESI学科分类 | PHYSICS
|
Scopus记录号 | 2-s2.0-85081957256
|
来源库 | Scopus
|
引用统计 |
被引频次[WOS]:40
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/106344 |
专题 | 工学院_生物医学工程系 |
作者单位 | 1.Department of Biomedical Engineering,Southern University of Science and Technology,Shenzhen, Guangdong,518055,China 2.School of Life Science and Technology,Harbin Institute of Technology,Harbin, Heilongjiang,15001,China 3.School of Physics,University of Electronic Science and Technology of China,Chengdu, Sichuan,610054,China 4.Department of Neurosurgery,West China Hospital Sichuan University,Chengdu, Sichuan,610041,China 5.Department of Anesthesiology,West China Hospital,Sichuan University,Chengdu, Sichuan,610041,China |
第一作者单位 | 生物医学工程系 |
通讯作者单位 | 生物医学工程系 |
第一作者的第一单位 | 生物医学工程系 |
推荐引用方式 GB/T 7714 |
Sun,Aihui,Guo,Heng,Gan,Qi,et al. Evaluation of visible NIR-I and NIR-II light penetration for photoacoustic imaging in rat organs[J]. OPTICS EXPRESS,2020,28(6):9002-9013.
|
APA |
Sun,Aihui,Guo,Heng,Gan,Qi,Yang,Lei,Liu,Qiang,&Xi,Lei.(2020).Evaluation of visible NIR-I and NIR-II light penetration for photoacoustic imaging in rat organs.OPTICS EXPRESS,28(6),9002-9013.
|
MLA |
Sun,Aihui,et al."Evaluation of visible NIR-I and NIR-II light penetration for photoacoustic imaging in rat organs".OPTICS EXPRESS 28.6(2020):9002-9013.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。