题名 | Ultrahigh-sensitivity label-free optical fiber biosensor based on a tapered singlemode- no core-singlemode coupler for Staphylococcus aureus detection |
作者 | |
通讯作者 | Wu,Qiang |
发表日期 | 2020-10-01
|
DOI | |
发表期刊 | |
ISSN | 0925-4005
|
EISSN | 0925-4005
|
卷号 | 320 |
摘要 | An ultra-high sensitivity label-free optical fiber biosensor for inactivated Staphylococcus aureus (S. aureus) detection is proposed and investigated in this study, with additional advantages of robust and stability compared to traditional tapered fiber structure. The proposed fiber biosensor is based on a tapered singlemode- no core-singlemode fiber coupler (SNSFC) structure, where the no core fiber was tapered to small diameter (taper-waist diameter of about 10 μm) and functionalized with the pig immunoglobulin G (IgG) antibody for detection of S. aureus. The measured maximum wavelength shift of the sensor for an S. aureus concentration of 7 × 10 CFU/mL (colony forming unit per milliliter) is 2.04 nm, which is equivalent to a limit of detection (LOD) of 3.1 CFU/mL (a highest LOD reported so far for optical fiber biosensors), considering the maximum wavelength variation of the sensor in phosphate buffered saline (PBS) is ±0.03 nm over 40 min, where 3 times of maximum wavelength variation (3 × 0.03 = 0.09 nm) is defined as measurement limit. The response time of the developed fiber sensor is less than 30 min. The ultra-sensitive biosensor has potential to be widely applied to various areas such as disease, medical diagnostics and food safety inspection. |
关键词 | |
相关链接 | [Scopus记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 其他
|
资助项目 | Nanchang Hangkong University graduate student innovation special fund project[YC2019049]
; Natural Science Foundation of Jiangxi Province[20192ACB20031][20192ACBL21051]
; State Key Laboratory of Advanced Optical Communication Systems and Networks, Shanghai Jiao Tong University, China[2018G2KF03003]
; National Natural Science Foundation of China[61665007][61465009]
; Major Academic and Technical Leaders Funding Program of Jiangxi,China[20172BCB22012]
|
WOS研究方向 | Chemistry
; Electrochemistry
; Instruments & Instrumentation
|
WOS类目 | Chemistry, Analytical
; Electrochemistry
; Instruments & Instrumentation
|
WOS记录号 | WOS:000558700900005
|
出版者 | |
EI入藏号 | 20202308784774
|
EI主题词 | Biosensors
; Chemical detection
; Mammals
; Optical fibers
; Antibodies
; Diagnosis
; Food safety
|
EI分类号 | Medicine and Pharmacology:461.6
; Immunology:461.9.1
; Fiber Optics:741.1.2
; Chemistry:801
; Food Products:822.3
|
ESI学科分类 | CHEMISTRY
|
Scopus记录号 | 2-s2.0-85085700273
|
来源库 | Scopus
|
引用统计 |
被引频次[WOS]:75
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/138089 |
专题 | 工学院_电子与电气工程系 |
作者单位 | 1.Key Laboratory of Nondestructive Test (Ministry of Education),Nanchang Hangkong University,Nanchang,330063,China 2.Faculty of Engineering and Environment,Northumbria University,Newcastle Upon Tyne,NE1 8ST,United Kingdom 3.State Key Lab Food Sci & Technol,Nanchang University,Nanchang,China 4.Research Center for Convergence Networks and Ubiquitous Services,University of Science & Technology Beijing,Beijing,100083,China 5.Department of Electrical and Electronic Engineering,Southern University of Science and Technology of China,Shenzhen,China |
推荐引用方式 GB/T 7714 |
Chen,Ling,Leng,Yuan Kui,Liu,Bin,et al. Ultrahigh-sensitivity label-free optical fiber biosensor based on a tapered singlemode- no core-singlemode coupler for Staphylococcus aureus detection[J]. SENSORS AND ACTUATORS B-CHEMICAL,2020,320.
|
APA |
Chen,Ling.,Leng,Yuan Kui.,Liu,Bin.,Liu,Juan.,Wan,Sheng Peng.,...&Wu,Qiang.(2020).Ultrahigh-sensitivity label-free optical fiber biosensor based on a tapered singlemode- no core-singlemode coupler for Staphylococcus aureus detection.SENSORS AND ACTUATORS B-CHEMICAL,320.
|
MLA |
Chen,Ling,et al."Ultrahigh-sensitivity label-free optical fiber biosensor based on a tapered singlemode- no core-singlemode coupler for Staphylococcus aureus detection".SENSORS AND ACTUATORS B-CHEMICAL 320(2020).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论