题名 | An Aptameric Biolayer Interferometric Assay for Detection of Recombinant Human Erythropoietin-α |
作者 | |
通讯作者 | GUO,Lei |
发表日期 | 2020-05-01
|
DOI | |
发表期刊 | |
ISSN | 0253-3820
|
EISSN | 1872-2040
|
卷号 | 48期号:5页码:670-675 |
摘要 | The biolayer interferometry (BLI), one promising biosensing technique for real-time, high-sensitive detection of analytes, is a new surface-sensitive spectroscopic technique in which the change of biolayer thickness is reflected by measuring the interferometric phase deflections. In our previous research, an ssDNA aptamer, 39nt, with definite interaction characteristics for recombinant human erythropoietin-α (EPO-α) was screened. In this work, a new aptameric BLI assay of EPO-α based on this aptamer 39nt was established. The biotinylated aptamer 39nt was firstly immobilized onto the optical fiber streptavidin biosensor chip, and the analytes in microliter volume were quickly diffused via high-speed vibration of 2200 r/min. The key parameters such as the orientation of aptamer sequence, the concentration for immobilization, and the overcome of nonspecific adsorption to exhibit the affinity recognition of aptamers were optimized. It was found that the 3'-end biotinylated aptamer 39nt with 50 nmol/L provided the best sensitivity, and the addition of Tween 20 and BSA could efficiently overcome nonspecific adsorption effect. Besides, towards the original designed disposable sensor chip, the affinity between protein EPO-α and ssDNA aptamer 39nt for ca. 10 times was still maintained under optimized regeneration condition, which reflected the operational flexibility of single-channel BLI system. Furthermore, a signal amplification approach of a sandwiched format via wheat germ agglutinin for detection of EPO-α was established, with the linear range of 10–200 nmol/L, and the LOD was 5 nmol/L. This assay was directly applied to the complex matrix such as 50% human plasma with recoveries in the range of 86.7%–104.2% and RSDs less than 15%. The BLI sensing system developed here provided a helpful way for practical applications in label-free protein interaction and detection. |
关键词 | |
相关链接 | [Scopus记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 其他
|
EI入藏号 | 20202008659342
|
EI主题词 | Proteins
; Optical fibers
; Signal processing
|
EI分类号 | Information Theory and Signal Processing:716.1
; Fiber Optics:741.1.2
; Organic Compounds:804.1
; Optical Variables Measurements:941.4
|
ESI学科分类 | CHEMISTRY
|
Scopus记录号 | 2-s2.0-85084454988
|
来源库 | Scopus
|
引用统计 |
被引频次[WOS]:0
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/138189 |
专题 | 南方科技大学第一附属医院 |
作者单位 | 1.State Key Laboratory of Toxicology and Medical Countermeasures,Institute of Toxicology and Pharmacology,Academy of Military Medical Sciences,Beijing,100850,China 2.Department of Spine Surgery and Institute for Orthopaedic Research,the 2 Clinical Medical College of Jinan University and the 1 Affiliated Hospital of Southern University of Science and Technology (Shenzhen People's Hospital),Shenzhen,518020,China 3.School of Public Health,Hebei Medical University,Shijiazhuang,050017,China |
第一作者单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
HE,Xiao Qin,LUO,Li,GUO,Lei,et al. An Aptameric Biolayer Interferometric Assay for Detection of Recombinant Human Erythropoietin-α[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2020,48(5):670-675.
|
APA |
HE,Xiao Qin,LUO,Li,GUO,Lei,&XIE,Jian Wei.(2020).An Aptameric Biolayer Interferometric Assay for Detection of Recombinant Human Erythropoietin-α.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,48(5),670-675.
|
MLA |
HE,Xiao Qin,et al."An Aptameric Biolayer Interferometric Assay for Detection of Recombinant Human Erythropoietin-α".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 48.5(2020):670-675.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论