中文版 | English
题名

Comparison of Common Methods for Precision Volume Measurement of Hematoma

作者
通讯作者Li, Zhong; Lin, Jiayun
发表日期
2020-07-17
DOI
发表期刊
ISSN
1748-670X
EISSN
1748-6718
卷号2020
摘要
Purpose. Our aim is to conduct analysis and comparison of some methods commonly used to measure the volume of hematoma, for example, slice method, voxelization method, and 3D-Slicer software method (projection method).Method. In order to validate the accuracy of the slice method, voxelization method, and 3D-Slicer method, these three methods were first applied to measure two known volumetric models, respectively. Then, a total of 198 patients diagnosed with spontaneous intracerebral hemorrhage (ICH) were recruited. The patients were split into 3 different groups based on the hematoma size: group 1:volume<10 ml(n=89), group 2: volume between 10 and 20 ml (n=59), and group 3:volume>20 ml(n=50). And the shape of the hematoma was classed into regular (round to ellipsoid) with smooth margins (n=76), irregular with frayed margins (n=85), and multilobular (n=37). The slice method, voxelization method, and 3D-Slicer method were adopted to measure the volume of hematoma, respectively, considering the nonclosed models and the models which may contain inaccurate normal information during CT scan. Moreover, the results were compared with the 3D-Slicer method for closed models.Results. There was a significant estimation error (P<0.05) using these three methods to calculate the volume of the closed hematoma model. The estimated hematoma volume was calculated to be14.2086743 +/- 0.900559087 ml,14.2119130 +/- 0.900851812 ml, and14.2123825 +/- 0.900835916 ml using slice method 1, slice method 2, and the voxelization method, respectively, compared to14.212656 +/- 0.900992371 ml using the 3D-Slicer method. The mean estimation error was-0.00398172 ml,-0.00074303 ml, and-0.00027354 ml caused by slice method 1, slice method 2, and voxelization method, respectively. There was a significant estimation error (P<0.05), applying these three methods to calculate the volume of the nonclosed hematoma model. The estimated hematoma volume was calculated to be14.1928246 +/- 0.902210314 ml using the 3D-Slicer method. The mean estimation error was calculated to be-0.00402121 ml,-0.00078237 ml, -0.00031288 ml, and-0.01983136 ml using slice method 1, slice method 2, voxelization method, and 3D-Slicer method, respectively.Conclusions. The 3D-Slicer software method is considered as a stable and capable method of high precision for the calculation of a closed hematoma model with correct normal direction, while it would be inappropriate for the nonclosed model nor the model with incorrect normal direction. The slice method and voxelization method can be the supplement and improvement of the 3D-Slicer software method, for the purpose of achieving precision medicine.
相关链接[来源记录]
收录类别
SCI ; EI
语种
英语
学校署名
其他
资助项目
National Natural Science Foundation of China[11671009][11801513] ; Zhejiang Provincial Natural Science Foundation of China[LZ19A010002][LQ18A010008]
WOS研究方向
Mathematical & Computational Biology
WOS类目
Mathematical & Computational Biology
WOS记录号
WOS:000556308600001
出版者
EI入藏号
20214511126821
EI主题词
Computerized tomography ; Errors ; Patient monitoring ; Volume measurement
EI分类号
Biological Materials and Tissue Engineering:461.2 ; Medicine and Pharmacology:461.6 ; Computer Applications:723.5 ; Mechanical Variables Measurements:943.2
来源库
Web of Science
引用统计
被引频次[WOS]:15
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/186698
专题南方科技大学
理学院
作者单位
1.Zhejiang Sci Tech Univ, Coll Sci, Hangzhou 310018, Zhejiang, Peoples R China
2.Hangzhou Normal Univ, Affiliated Hosp, Hangzhou 310015, Zhejiang, Peoples R China
3.Southern Univ Sci & Technol, Coll Sci, Shenzhen 518055, Guangdong, Peoples R China
推荐引用方式
GB/T 7714
Chen, Minhong,Li, Zhong,Ding, Jianping,et al. Comparison of Common Methods for Precision Volume Measurement of Hematoma[J]. Computational and Mathematical Methods in Medicine,2020,2020.
APA
Chen, Minhong,Li, Zhong,Ding, Jianping,Lu, Xingqi,Cheng, Yinan,&Lin, Jiayun.(2020).Comparison of Common Methods for Precision Volume Measurement of Hematoma.Computational and Mathematical Methods in Medicine,2020.
MLA
Chen, Minhong,et al."Comparison of Common Methods for Precision Volume Measurement of Hematoma".Computational and Mathematical Methods in Medicine 2020(2020).
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Chen, Minhong]的文章
[Li, Zhong]的文章
[Ding, Jianping]的文章
百度学术
百度学术中相似的文章
[Chen, Minhong]的文章
[Li, Zhong]的文章
[Ding, Jianping]的文章
必应学术
必应学术中相似的文章
[Chen, Minhong]的文章
[Li, Zhong]的文章
[Ding, Jianping]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论