中文版 | English
题名

Multiomic analysis of a dried single-drop plasma sample using an integrated mass spectrometry approach

作者
通讯作者Tian,Ruijun
发表日期
2020-10-21
DOI
发表期刊
ISSN
0003-2654
EISSN
1364-5528
卷号145期号:20页码:6441-6446
摘要

An easy-to-use and fast approach was developed for integrated proteomic and metabolic profiling in a dried single-drop plasma sample. Plasma collection, room temperature storage, and sample preparation for both proteins and metabolites were seamlessly integrated in one spintip device. MS-based multiomic profiling using the same nano LC-MS system identified more than 150 proteins and 160 metabolites from the 1 μL plasma sample in 6 hours. Further combination with micro-flow LC and targeted MS made it a promising approach for the fast profiling of molecular biomarkers with high sensitivity and accuracy.

相关链接[Scopus记录]
收录类别
SCI ; EI
语种
英语
学校署名
第一 ; 通讯
资助项目
National Natural Science Foundation of China[31700088][91953118] ; Shenzhen Key Laboratory of Marine Archaea Geo-Omics[ZDSYS201802081843490] ; China State Key Basic Research Program[2016YFA0501403][2016YFA0501404] ; Guangdong Provincial Fund for Distinguished Young Scholars[2019B151502050] ; Guangdong Provincial Natural Science Grant[2016A030312016] ; Shenzhen Innovation of Science and Technology Commission[JCYJ20170412154126026]
WOS研究方向
Chemistry
WOS类目
Chemistry, Analytical
WOS记录号
WOS:000576736000003
出版者
EI入藏号
20204409413368
EI主题词
Metabolites ; Drops ; Mass spectrometry
EI分类号
Chemistry:801 ; Organic Compounds:804.1
ESI学科分类
CHEMISTRY
Scopus记录号
2-s2.0-85092802807
来源库
Scopus
引用统计
被引频次[WOS]:3
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/203743
专题理学院_化学系
作者单位
1.Department of Chemistry,Southern University of Science and Technology,Shenzhen,518055,China
2.Department of Chemistry,Southern University of Science and Technology,Shenzhen,518055,China
第一作者单位化学系
通讯作者单位化学系
第一作者的第一单位化学系
推荐引用方式
GB/T 7714
Gao,Weina,Zhang,Qiaoyun,Su,Yiran,et al. Multiomic analysis of a dried single-drop plasma sample using an integrated mass spectrometry approach[J]. ANALYST,2020,145(20):6441-6446.
APA
Gao,Weina.,Zhang,Qiaoyun.,Su,Yiran.,Huang,Peiwu.,Lu,Xue.,...&Tian,Ruijun.(2020).Multiomic analysis of a dried single-drop plasma sample using an integrated mass spectrometry approach.ANALYST,145(20),6441-6446.
MLA
Gao,Weina,et al."Multiomic analysis of a dried single-drop plasma sample using an integrated mass spectrometry approach".ANALYST 145.20(2020):6441-6446.
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Gao,Weina]的文章
[Zhang,Qiaoyun]的文章
[Su,Yiran]的文章
百度学术
百度学术中相似的文章
[Gao,Weina]的文章
[Zhang,Qiaoyun]的文章
[Su,Yiran]的文章
必应学术
必应学术中相似的文章
[Gao,Weina]的文章
[Zhang,Qiaoyun]的文章
[Su,Yiran]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。