题名 | Comparison of low-power magnification one-layer vasovasostomy with stent and microscopic two-layer vasovasostomy for vasectomy reversal |
作者 | |
通讯作者 | Jiang, Hongtao |
发表日期 | 2020-11
|
DOI | |
发表期刊 | |
ISSN | 0955-9930
|
EISSN | 1476-5489
|
卷号 | 32期号:6页码:617-622 |
摘要 | This study aimed to evaluate a simplified vasovasostomy procedure that shortens the operative time. This was a retrospective (non-randomized) study of men who underwent bilateral vasectomy and consulted for vasovasostomy (02/2014-08/2016). Eight interrupted sutures were used for one-layer full-thickness vasal anastomosis over a 20 or 22 G catheter temporarily inserted in the lumen of the anastomotic site as a stent. Control patients underwent double-layer vasovasostomy. The surgery was significantly shorter in the one-layer group (n = 23) (62 +/- 8 vs. 133 +/- 15 min, P < 0.001 vs. the two-layer group, (n = 19)). There was no difference in patency between the two groups (95.7 vs. 94.7%, P > 0.999). There was one case of epididymitis in each group. There were no complications like bleeding, scrotal hematoma, hydrocele, or infection. Low-power microscopic one-layer vasovasostomy with stent was simple and had a short operation time. The patency could be similar to that of two-layer vasovasostomy, but prospective studies are necessary for confirmation. |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 通讯
|
WOS研究方向 | Urology & Nephrology
|
WOS类目 | Urology & Nephrology
|
WOS记录号 | WOS:000587900100008
|
出版者 | |
ESI学科分类 | CLINICAL MEDICINE
|
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:1
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/210473 |
专题 | 南方科技大学第一附属医院 |
作者单位 | 1.Fujian Med Univ, Union Hosp, Dept Urol, Fuzhou, Peoples R China 2.Xiamen Univ, ZhongShan Hosp, Dept Urol, Xiamen, Peoples R China 3.Southern Univ Sci & Technol, Jinan Univ, Affiliated Hosp 1,Minimally Invas Urol Shenzhen R, Clin Med Coll 2,Shenzhen Peoples Hosp,Dept Urol, Shenzhen 518020, Peoples R China |
通讯作者单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
Wang, Bin,Liu, Ziming,Jiang, Hongtao. Comparison of low-power magnification one-layer vasovasostomy with stent and microscopic two-layer vasovasostomy for vasectomy reversal[J]. INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH,2020,32(6):617-622.
|
APA |
Wang, Bin,Liu, Ziming,&Jiang, Hongtao.(2020).Comparison of low-power magnification one-layer vasovasostomy with stent and microscopic two-layer vasovasostomy for vasectomy reversal.INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH,32(6),617-622.
|
MLA |
Wang, Bin,et al."Comparison of low-power magnification one-layer vasovasostomy with stent and microscopic two-layer vasovasostomy for vasectomy reversal".INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH 32.6(2020):617-622.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论