题名 | Age and gender dependence of liver diffusion parameters and the possibility that intravoxel incoherent motion modeling of the perfusion component is constrained by the diffusion component |
作者 | |
通讯作者 | Wang, Yi Xiang J. |
发表日期 | 2021-03-01
|
DOI | |
发表期刊 | |
ISSN | 0952-3480
|
EISSN | 1099-1492
|
卷号 | 34期号:3 |
摘要 | The aim of this study was to establish reference values for middle-aged subjects and to investigate the age and gender dependence of liver diffusion MRI parameters. The IVIM type of liver diffusion scan was based on a single-shot spin-echo-type echo-planar sequence using a 1.5 T magnet with 16 b-values. Diffusion-derived vessel density (DDVD)(b0b2) or DDVD(b0b10) was the signal difference between b = 0 and b = 2 (or b = 10) s/mm(2) images after removing visible vessels. IVIM analysis was performed with full fitting and segmented fitting, and with a threshold b-value of 60 or 200 s/mm(2), and fitting started from b = 2 s/mm(2). Thirty-one men (age range: 25-71 years) and 26 men (age: 22-69 years) had DDVD and IVIM analysis, respectively, while 37 women (age: 20-71 years) and 36 women (age: 20-71 years) had DDVD and IVIM analysis, respectively. DDVD results showed a significant age-related reduction for women. IVIM results for full fitting showed excellent agreement with those for segmented fitting using a threshold b of 60 s/mm(2), but this was less good for results with a threshold b of 200 s/mm(2). As age increased, female subjects' D-slow measure showed a significant reduction, while their PF and D-fast measures showed a significant increase. For the age group of 40-55 years, DDVD(b0b2), DDVD(b0b10), D-slow, PF and D-fast were 12.26 +/- 3.90 au/pixel, 16.95 +/- 5.45 au/pixel, 1.072 +/- 0.067 (10(-3) mm(2)/s), 0.141 +/- 0.025 and 61.0 +/- 14.0 (10(-3) mm(2)/s) for men, and 13.35 +/- 3.6 au/pixel, 17.20 +/- 3.62 au/pixel, 1.069 +/- 0.074 (10(-3) mm(2)/s), 0.119 +/- 0.014 and 57.1 +/- 13.2 (10(-3) mm(2)/s) for women, respectively. DDVD measure of this study suggest that aging is associated with a reduction in liver perfusion. There is a possibility that a lower D-slow measure is associated with artificially higher PF and D-fast measures, and that IVIM modeling of the perfusion component is constrained by the diffusion component. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
|
资助项目 | Hong Kong GRF[14109218]
; Sanming Project of Medicine in Shenzhen[SZSM201612053]
|
WOS研究方向 | Biophysics
; Radiology, Nuclear Medicine & Medical Imaging
; Spectroscopy
|
WOS类目 | Biophysics
; Radiology, Nuclear Medicine & Medical Imaging
; Spectroscopy
|
WOS记录号 | WOS:000600886400001
|
出版者 | |
ESI学科分类 | CLINICAL MEDICINE
|
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:23
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/221070 |
专题 | 南方科技大学第二附属医院 |
作者单位 | 1.Southern Univ Sci & Technol, Natl Clin Res Ctr Infect Dis, Affiliated Hosp 2, Peoples Hosp Shenzhen 3,Dept Radiol, Shenzhen, Guangdong, Peoples R China 2.Chinese Univ Hong Kong, Fac Med, Dept Imaging & Intervent Radiol, Shatin, Hong Kong, Peoples R China |
第一作者单位 | 南方科技大学第二附属医院 |
第一作者的第一单位 | 南方科技大学第二附属医院 |
推荐引用方式 GB/T 7714 |
Huang, Hua,Zheng, Cun-Jing,Wang, Li-Fei,et al. Age and gender dependence of liver diffusion parameters and the possibility that intravoxel incoherent motion modeling of the perfusion component is constrained by the diffusion component[J]. NMR IN BIOMEDICINE,2021,34(3).
|
APA |
Huang, Hua,Zheng, Cun-Jing,Wang, Li-Fei,Che-Nordin, Nazmi,&Wang, Yi Xiang J..(2021).Age and gender dependence of liver diffusion parameters and the possibility that intravoxel incoherent motion modeling of the perfusion component is constrained by the diffusion component.NMR IN BIOMEDICINE,34(3).
|
MLA |
Huang, Hua,et al."Age and gender dependence of liver diffusion parameters and the possibility that intravoxel incoherent motion modeling of the perfusion component is constrained by the diffusion component".NMR IN BIOMEDICINE 34.3(2021).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论