题名 | Filtering-induced time shifts in photoplethysmography pulse features measured at different body sites: the importance of filter definition and standardization |
作者 | |
通讯作者 | Chen, Fei; Zheng, Dingchang |
发表日期 | 2021-07-01
|
DOI | |
发表期刊 | |
ISSN | 0967-3334
|
EISSN | 1361-6579
|
卷号 | 42期号:7 |
摘要 | Objective. The waveform of a photoplethysmography (PPG) signal depends on the measurement site and individual physiological conditions. Filtering can distort the morphology of the original PPG signal waveform and change the timing of pulse feature points on PPG signals. We aim to quantitatively investigate the effect of PPG signal morphology (related to measurement site) and type of pulse feature on the filtering-induced time shift (TS). Approach. 60 s PPG signals were measured from six body sites (finger, wrist under (volar), wrist upper (dorsal), earlobe, and forehead) of 36 healthy adults. Using infinite impulse response digital filters which are common in PPG signal processing, PPG signals were prefiltered (band-pass, pass and stop bands: >0.5 Hz and <0.2 Hz for high-pass filter, 30 Hz for low-pass filter) and then filtered (low-pass, pass and stop bands: 5 Hz). Four pulse feature points were defined and extracted (peak, valley, maximal first derivative, and maximal second derivative). For each subject, overall TS and intra-subject TS variability in feature points were calculated as the mean and standard deviation of TS between prefiltered and filtered PPG signals in 50 cardiac cycles. Statistical testing was performed to investigate the effect of measurement site and type of pulse feature on overall TS and intra-subject TS variability. Main results. Measurement site, type of pulse feature, and their interaction had significant impacts on the overall TS and intra-subject TS variability (p < 0.001 for all). Valley and maximal second derivative showed higher overall TS than peak and maximal first derivative. Finger had higher overall TS and lower intra-subject TS variability than other measurement sites. Significance. Measurement site and type of pulse feature can significantly influence the timing of feature points on filtered PPG signals. Filtering parameters should be quoted to support the reproducibility of PPG-related studies. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 通讯
|
资助项目 | Southern University of Science and Technology[G02236002]
|
WOS研究方向 | Biophysics
; Engineering
; Physiology
|
WOS类目 | Biophysics
; Engineering, Biomedical
; Physiology
|
WOS记录号 | WOS:000679080900001
|
出版者 | |
EI入藏号 | 20215211392260
|
EI主题词 | High pass filters
; Impulse response
; Morphology
; Photoplethysmography
; Standardization
|
EI分类号 | Medicine and Pharmacology:461.6
; Electric Filters:703.2
; Codes and Standards:902.2
; Physical Properties of Gases, Liquids and Solids:931.2
; Materials Science:951
|
ESI学科分类 | BIOLOGY & BIOCHEMISTRY
|
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:27
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/242699 |
专题 | 工学院_电子与电气工程系 |
作者单位 | 1.Coventry Univ, Res Ctr Intelligent Healthcare, Coventry CV1 5FB, W Midlands, England 2.Southern Univ Sci & Technol, Dept Elect & Elect Engn, Shenzhen 518055, Peoples R China |
通讯作者单位 | 电子与电气工程系 |
推荐引用方式 GB/T 7714 |
Liu, Haipeng,Allen, John,Khalid, Syed Ghufran,et al. Filtering-induced time shifts in photoplethysmography pulse features measured at different body sites: the importance of filter definition and standardization[J]. PHYSIOLOGICAL MEASUREMENT,2021,42(7).
|
APA |
Liu, Haipeng,Allen, John,Khalid, Syed Ghufran,Chen, Fei,&Zheng, Dingchang.(2021).Filtering-induced time shifts in photoplethysmography pulse features measured at different body sites: the importance of filter definition and standardization.PHYSIOLOGICAL MEASUREMENT,42(7).
|
MLA |
Liu, Haipeng,et al."Filtering-induced time shifts in photoplethysmography pulse features measured at different body sites: the importance of filter definition and standardization".PHYSIOLOGICAL MEASUREMENT 42.7(2021).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论