题名 | Effects of Grip-Load Force and Muscle Fatigue on fNIRS Signal during Handgrip Voluntary Contraction Task |
作者 | |
通讯作者 | Chen, Fei |
DOI | |
发表日期 | 2019
|
ISSN | 19483554
|
ISBN | 978-1-5386-7922-7
|
会议录名称 | |
卷号 | 2019-March
|
页码 | 510-513
|
会议日期 | 20-23 March 2019
|
会议地点 | San Francisco, CA, United states
|
出版地 | 345 E 47TH ST, NEW YORK, NY 10017 USA
|
出版者 | |
摘要 | The studies of grip-load force and muscle fatigue characteristics are of great significance in rehabilitation and sports medicine. Functional near-infrared spectroscopy (fNIRS) is generally used to investigate cerebral oxygenation changes during a motor task. In this study, the effects of force load and muscle fatigue on fNIRS signal features during a handgrip voluntary contraction task were quantitatively investigated. Twenty-four healthy subjects performed isometric grasping contractions at the conditions of 30% and 50% of the maximal voluntary contraction (MVC) with his/ her dominant or non-dominant hand. Experimental results showed that the average change rate of oxygenated hemoglobin (HbO(2)) concentrations at the condition of 30% MVC hand muscle strength was significantly smaller than that at the condition of 50% MVC hand muscle strength. However, the total change of HbO(2) concentration in conditions of the 30% and 50% MVC hand muscle strength were in good agreement. The total change of HbO(2) concentration and the average change rate of HbO(2) concentration were not significantly different between the dominant and non-dominant hands. |
关键词 | |
学校署名 | 第一
; 通讯
|
语种 | 英语
|
相关链接 | [来源记录] |
收录类别 | |
资助项目 | National Key Research and Development Program of China[2018YFC1312000]
|
WOS研究方向 | Engineering
; Neurosciences & Neurology
|
WOS类目 | Engineering, Biomedical
; Neurosciences
|
WOS记录号 | WOS:000469933200125
|
EI入藏号 | 20192307018244
|
EI主题词 | Infrared devices
; Muscle
; Near infrared spectroscopy
; Sports medicine
|
EI分类号 | Biological Materials and Tissue Engineering:461.2
; Medicine and Pharmacology:461.6
; Imaging Techniques:746
|
来源库 | Web of Science
|
全文链接 | https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8716927 |
引用统计 |
被引频次[WOS]:3
|
成果类型 | 会议论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/24535 |
专题 | 工学院_电子与电气工程系 |
作者单位 | 1.Southern Univ Sci & Technol, Dept Elect & Elect Engn, Shenzhen, Peoples R China 2.Harbin Inst Technol Shenzhen, Dept Elect & Informat Engn, Shenzhen, Guandgong, Peoples R China 3.Capital Med Univ, Xuanwu Hosp, Natl Clin Res Ctr Geriatr Disorders, Beijing, Peoples R China 4.Peng Cheng Lab, Shenzhen, Guangdong, Peoples R China |
第一作者单位 | 电子与电气工程系 |
通讯作者单位 | 电子与电气工程系 |
第一作者的第一单位 | 电子与电气工程系 |
推荐引用方式 GB/T 7714 |
Guo, Zengzhi,Ma, Ting,Chen, Fei. Effects of Grip-Load Force and Muscle Fatigue on fNIRS Signal during Handgrip Voluntary Contraction Task[C]. 345 E 47TH ST, NEW YORK, NY 10017 USA:IEEE,2019:510-513.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论