题名 | Real-time attitude tracking of capsule endoscope based on MEMS IMU and error analysis |
作者 | |
通讯作者 | Hu,Chengzhi |
DOI | |
发表日期 | 2021-07-15
|
ISBN | 978-1-6654-3679-3
|
会议录名称 | |
页码 | 968-973
|
会议日期 | 15-19 July 2021
|
会议地点 | Xining, China
|
摘要 | Wireless capsule endoscope (WCE) has been increasingly exploited for noninvasive screening and diagnosis of the entire esophagus, stomach, colon, and small intestine. WCE allows direct visualization of gastrointestinal tracts and causes less pain to the patients. Automated navigation of WCE during the medical procedure will significantly reduce the testing time and improve the usage and efficiency of medical infrastructure. Attitude tracking of WCE is of great importance for real-time tracking of the position and orientation of capsule endoscope. In this paper, a method for calculating the attitude of WCE based on MEMS IMU (Inertial Measurement Units) is implemented. The accuracy of attitude tracking is measured by a series of experiments. By reorientating the capsule endoscope with a high precision 3D rotary stage, the error from the proposed algorism is determined. The experimental results show that the attitude of WCE based on MEMS IMU can meet the diagnostic requirements in about six minutes, but the performance cannot be maintained due to error accumulation. Additionally, we propose a method to improve the attitude accuracy by reciprocating the rotational motion during the inspection process. |
关键词 | |
学校署名 | 第一
; 通讯
|
语种 | 英语
|
相关链接 | [Scopus记录] |
收录类别 | |
EI入藏号 | 20213910935907
|
EI主题词 | Errors
; Navigation
; Tracking (position)
|
EI分类号 | Medicine and Pharmacology:461.6
|
Scopus记录号 | 2-s2.0-85115395063
|
来源库 | Scopus
|
全文链接 | https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9517523 |
引用统计 |
被引频次[WOS]:0
|
成果类型 | 会议论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/253528 |
专题 | 工学院_机械与能源工程系 |
作者单位 | 1.Southern University of Science and Technology,Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems,Department of Mechanical and Energy Engineering,Shenzhen,518055,China 2.Guangdong Prov. Key Laboratory of Human-Augmentation and Rehabilitation Robotics in Universities,Southern University of Science and Technology,Shenzhen,518055,China |
第一作者单位 | 机械与能源工程系 |
通讯作者单位 | 机械与能源工程系; 南方科技大学 |
第一作者的第一单位 | 机械与能源工程系 |
推荐引用方式 GB/T 7714 |
Huang,Zhuokang,Hu,Chengzhi. Real-time attitude tracking of capsule endoscope based on MEMS IMU and error analysis[C],2021:968-973.
|
条目包含的文件 | 条目无相关文件。 |
|