摘要 | Non-invasive blood glucose monitoring at microwave frequencies is generally thought to be unreliable in terms of reproducibility of measurements. The failure to reproduce a blood glucose measurement from one experiment to another is in major part due to the unwanted interaction of leaky waves between the ambient environment and the blood glucose measuring device. In this work, we have overcome this problem by simply eliminating the leaky modes through the use of surface electromagnetic waves from a curved Goubau line. In the proposed methodology, a fixed volume of blood-filled skin tissue was first formed by vacuum suction and partially wound with a curved Goubau line which was coated with a 3 mm thick layer of gelatin/glycerin composite. Blood glucose levels were non-invasively determined using a network analyzer. At 4.5 GHz, a near-linear correlation exists between the measured S12 parameters and the blood glucose levels. The measured correlation was highly reproducible and consistent with the measurements obtained using the conventional invasive lancing approach. The findings of this work suggest the feasibility of non-invasive detection of left and right imbalances in the body. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 其他
|
WOS研究方向 | Engineering
|
WOS类目 | Engineering, Electrical & Electronic
|
WOS记录号 | WOS:000475354700068
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:21
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/25762 |
专题 | 工学院_电子与电气工程系 |
作者单位 | 1.Vietnamese German Univ, Fac Engn, Thu Dau Mot 820000, Vietnam 2.Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518000, Peoples R China 3.Southern Univ Sci & Technol, Dept Elect & Elect Engn, 1 Pk A7, Shenzhen 518055, Peoples R China |
推荐引用方式 GB/T 7714 |
Liu, Louis W. Y.,Kandwal, Abhishek,Cheng, Qingsha,et al. Non-Invasive Blood Glucose Monitoring Using a Curved Goubau Line[J]. Electronics,2019,8(6).
|
APA |
Liu, Louis W. Y.,Kandwal, Abhishek,Cheng, Qingsha,Shi, Hongjian,Tobore, Igbe,&Nie, Zedong.(2019).Non-Invasive Blood Glucose Monitoring Using a Curved Goubau Line.Electronics,8(6).
|
MLA |
Liu, Louis W. Y.,et al."Non-Invasive Blood Glucose Monitoring Using a Curved Goubau Line".Electronics 8.6(2019).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论