题名 | Evaluation of gas chromatography-atmospheric pressure chemical ionization tandem mass spectrometry as an alternative to gas chromatography tandem mass spectrometry for the determination of polychlorinated biphenyls and polybrominated diphenyl ethers |
作者 | |
通讯作者 | Xu, Shunqing; Cai, Zongwei |
发表日期 | 2019-06
|
DOI | |
发表期刊 | |
ISSN | 0045-6535
|
EISSN | 1879-1298
|
卷号 | 225页码:288-294 |
摘要 | A method for the analysis of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in serum was developed using gas chromatography coupled to tandem mass spectrometry with atmospheric pressure chemical ionization (GC-APCI-MS/MS). The ionization and fragmentation performance of APCI were evaluated and compared with those of electron ionization (EI). In contrast to extensive fragmentation caused by El with high energy, soft ionization achieved by APCI produced mass spectra dominated by molecular ions from the first stage of MS analysis. Better sensitivity and selectivity achieved by the GC-APCI-MS/MS method allowed to analyze serum samples with a low volume (100 mu L). The limits of detection (LODs) ranged from 0.067 to 14 pg/mL for the analysis in serum samples. The developed method was evaluated at three spiking levels (0.05, 0.5 and 5 ng/mL for PCBs), showing good recoveries and repeatability. The recoveries ranged from 74.0% to 130.5%, and the relative standard deviations (RSDs) were less than 20%, for all analytes. The determination of PCBs and PBDEs in the human serum samples by GC-APCI-MS/MS was compared with gas chromatography -tandem mass spectrometry with El (GC-EI-MS/MS). BDE-99 and BDE-100 were successfully quantified by GC-APCI-MS/MS, while these two PBDE congeners were not detected by GC-EI-MS/MS. The GC-APCI-MS/MS method had a clear advantage when analyzing compounds at low levels. (C) 2019 Elsevier Ltd. All rights reserved. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 其他
|
资助项目 | National Natural Science Foundation of China[21437002]
|
WOS研究方向 | Environmental Sciences & Ecology
|
WOS类目 | Environmental Sciences
|
WOS记录号 | WOS:000467668500032
|
出版者 | |
EI入藏号 | 20191206663868
|
EI主题词 | Atmospheric chemistry
; Atmospheric ionization
; Atmospheric pressure
; Body fluids
; Ethers
; Mass spectrometry
; Organic pollutants
; Polychlorinated biphenyls
|
EI分类号 | Atmospheric Properties:443.1
; Biological Materials and Tissue Engineering:461.2
; Chemistry:801
; Chemical Operations:802.3
; Organic Compounds:804.1
|
ESI学科分类 | ENVIRONMENT/ECOLOGY
|
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:11
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/25789 |
专题 | 工学院_环境科学与工程学院 |
作者单位 | 1.Hong Kong Baptist Univ, Dept Chem, State Key Lab Environm & Biol Anal, Hong Kong, Peoples R China 2.Fuzhou Univ, Coll Chem, MOE Key Lab Analyt Sci Food Safety & Biol, Fuzhou 350116, Fujian, Peoples R China 3.Huazhong Univ Sci & Technol, Sch Publ Hlth, Minist Educ, Key Lab Environm & Hlth, Wuhan, Hubei, Peoples R China 4.Huazhong Univ Sci & Technol, Sch Publ Hlth, Minist Environm Protect, Wuhan, Hubei, Peoples R China 5.Huazhong Univ Sci & Technol, Sch Publ Hlth, State Key Lab Environm Hlth Incubat, Wuhan, Hubei, Peoples R China 6.Southern Univ Sci & Technol, Sch Environm Sci & Engn, Guangdong Prov Key Lab Soil & Groundwater Pollut, Shenzhen, Peoples R China 7.Educ Univ Hong Kong, CHEER, Hong Kong, Peoples R China |
推荐引用方式 GB/T 7714 |
Fang, Jing,Zhao, Hongzhi,Zhang, Yanhao,et al. Evaluation of gas chromatography-atmospheric pressure chemical ionization tandem mass spectrometry as an alternative to gas chromatography tandem mass spectrometry for the determination of polychlorinated biphenyls and polybrominated diphenyl ethers[J]. CHEMOSPHERE,2019,225:288-294.
|
APA |
Fang, Jing.,Zhao, Hongzhi.,Zhang, Yanhao.,Wong, Minghung.,He, Yu.,...&Cai, Zongwei.(2019).Evaluation of gas chromatography-atmospheric pressure chemical ionization tandem mass spectrometry as an alternative to gas chromatography tandem mass spectrometry for the determination of polychlorinated biphenyls and polybrominated diphenyl ethers.CHEMOSPHERE,225,288-294.
|
MLA |
Fang, Jing,et al."Evaluation of gas chromatography-atmospheric pressure chemical ionization tandem mass spectrometry as an alternative to gas chromatography tandem mass spectrometry for the determination of polychlorinated biphenyls and polybrominated diphenyl ethers".CHEMOSPHERE 225(2019):288-294.
|
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | 操作 | |
Fang-2019-Evaluation(700KB) | -- | -- | 限制开放 | -- |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论