中文版 | English
题名

Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis

作者
通讯作者Yun,Cai
发表日期
2021
DOI
发表期刊
ISSN
0020-1383
EISSN
1879-0267
卷号53期号:2
摘要
Background: The cross-sectional area of three parallel screws might affect the stability of the internal fixation of femoral neck fractures. The screws fixed in the oblique-triangle configuration (OTC) were assumed to have a larger cross-sectional area, but the biomechanical stability has not yet been validated. In this study, finite element analyses were performed to compare the biomechanical properties of the internal fixation fixed by the OTC and the traditional Inverted Equilateral Triangle Configuration (IETC). Method: Pauwels type III fracture was established on the three-dimensional femoral model and three cannulated screws with the OTC and traditional IETC methods were applied. The oblique-triangle configuration with the largest area inscribed the femoral neck isthmus by the three screws was determined, the area and circumference of the cross-section formed by the OTC and IETC model were compared. Stress, strain, and displacement peaks of the two configuration models under different loads were compared. Twelve pairs of nodes on the fracture ends were selected and the displacement of the fracture ends was evaluated through the displacement between these nodes. Results: The area and circumference of the cross-section formed by the OTC were larger than those in the IETC model. The degree of stress dispersion around the screw holes in the OTC model was better than that of the IETC, but the stress distribution order of the three screws in the two models was consistent. The maximum stress, strain, displacement, and displacement of the fracture end in the OTC model were smaller than those in the IETC model. The stress, strain, displacement, and fracture end displacement peaks of the two fixed models gradually increase with the increase of loads. Conclusion: The oblique-triangle configuration showed superior mechanical properties than the IETC in finite element analyses. This study suggests that when three screws are fixed in parallel method, the larger the cross-sectional area of the screw configuration, the better stability of the internal fixation might be obtained. Furthermore, the biomechanical properties of various spatial configurations and screw holes of the three parallel screws need to be considered before clinical practice.
关键词
相关链接[Scopus记录]
收录类别
语种
英语
学校署名
其他
WOS研究方向
General & Internal Medicine ; Emergency Medicine ; Orthopedics ; Surgery
WOS类目
Critical Care Medicine ; Emergency Medicine ; Orthopedics ; Surgery
WOS记录号
WOS:000749798400020
出版者
ESI学科分类
CLINICAL MEDICINE
Scopus记录号
2-s2.0-85119999133
来源库
Scopus
引用统计
被引频次[WOS]:11
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/258207
专题南方科技大学医院
作者单位
1.Department of Orthopaedics,Shijingshan Teaching Hospital of Capital Medical University,Beijing Shijingshan Hospital,Beijing,No. 24, Shijingshan Road,100043,China
2.The Faculty of Orthopaedics,The Fourth Medical Center,Chinese PLA General Hospital,Beijing,China
3.National Clinical Research Center for Orthopaedics,Sports Medicine & Rehabilitation,Beijing,100853,China
4.Department of Orthopaedics,Beijing Tsinghua Changgung Hospital,School of Clinical Medicine,Tsinghua University,Beijing,102218,China
5.Department of Orthopaedics,Southern University of Science and Technology Hospital,Shenzhen,518055,China
推荐引用方式
GB/T 7714
Zhang,Ru Yi,Li,Jian Tao,Zhao,Jing Xin,et al. Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis[J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED,2021,53(2).
APA
Zhang,Ru Yi.,Li,Jian Tao.,Zhao,Jing Xin.,Zhao,Zhe.,Zhang,Li Cheng.,...&Tang,Pei Fu.(2021).Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis.INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED,53(2).
MLA
Zhang,Ru Yi,et al."Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis".INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED 53.2(2021).
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Zhang,Ru Yi]的文章
[Li,Jian Tao]的文章
[Zhao,Jing Xin]的文章
百度学术
百度学术中相似的文章
[Zhang,Ru Yi]的文章
[Li,Jian Tao]的文章
[Zhao,Jing Xin]的文章
必应学术
必应学术中相似的文章
[Zhang,Ru Yi]的文章
[Li,Jian Tao]的文章
[Zhao,Jing Xin]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。