题名 | SCREENING BREAST LESIONS USING SHEAR MODULUS AND ITS 1-MM SHELL IN SOUND TOUCH ELASTOGRAPHY |
作者 | |
通讯作者 | Dong, Fajin |
发表日期 | 2019-03
|
DOI | |
发表期刊 | |
ISSN | 0301-5629
|
EISSN | 1879-291X
|
卷号 | 45期号:3页码:710-719 |
摘要 | The aim of the study described here was to screen breast lesions using either or both shear modulus (G) and its 1-mm shell (S) in sound touch elastography through a retrospective study of 209 consecutive women with breast lesions. The ability of G and S data to differentiate between malignant and benign lesions was evaluated using the receiver operating characteristic (ROC) curve. The optimal cutoff point, sensitivity, specificity, positive likelihood ratio (LR+) and negative likelihood ratio (LR-) were calculated. Then, the parameters were pooled to determine the area under the summary receiver operating curve (AUSROC). The pooled sensitivity (PSen), pooled specificity (PSpe), pooled LR+ (PLR+), pooled LR- (PLR-) and diagnostic score (DS) were calculated. Pathologic examination results were used as the reference. In total, 209 patients with 155 benign and 54 malignant lesions were enrolled. For G(max), G(mean) and G(sd), the cutoff values were 35.15 kPa (p = 0.0001), 10.18 kPa (p = 0.0001) and 5.18 kPa (p = 0.0001), respectively. For S-max, S-mean and S-sd, the cutoff values were 40.94 kPa (p = 0.001), 13.12 kPa (p = 0.0001) and 7.97 kPa (p = 0.0001), respectively. There were no significant differences in G(min) and S-min between benign and malignant lesions. For the pooled six parameters, the PSen, PSpe, PLR+, PLR-, DS and AUSROC were 86% (95% confidence interval: 82%-89%), 82% (80%-85%), 4.90 (4.24-5.68), 0.17 (0.13-0.22), 3.36 (3.00-3.72) and 91% (88-93%), respectively. The G and S parameters of sound touch elastography could provide valuable data for the evaluation of breast lesions. Additionally, use of multiple parameters or combined use of the six parameters may be more effective in the evaluation of breast lesions. (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
; 通讯
|
资助项目 | Clinical Project of Shenzhen People's Hospital[SYLY201702]
|
WOS研究方向 | Acoustics
; Radiology, Nuclear Medicine & Medical Imaging
|
WOS类目 | Acoustics
; Radiology, Nuclear Medicine & Medical Imaging
|
WOS记录号 | WOS:000457853400010
|
出版者 | |
EI入藏号 | 20190206361262
|
EI主题词 | Diagnosis
; Elastic moduli
; Parameter estimation
; Scattering parameters
; Shear strain
; Touch screens
; Ultrasonography
|
ESI学科分类 | CLINICAL MEDICINE
|
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:9
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/26308 |
专题 | 南方科技大学第一附属医院 |
作者单位 | 1.Jinan Univ, Clin Coll 2, Southern Univ Sci & Technol,Shenzhen Peoples Hosp, Dept Ultrasound,Affiliated Hosp 1,Shenzhen Med Ul, Shenzhen 518020, Peoples R China 2.Guangzhou Med Univ, Guangzhou, Guangdong, Peoples R China |
第一作者单位 | 南方科技大学第一附属医院 |
通讯作者单位 | 南方科技大学第一附属医院 |
第一作者的第一单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
Zhang, Lei,Xu, Jinfeng,Wu, Huaiyu,et al. SCREENING BREAST LESIONS USING SHEAR MODULUS AND ITS 1-MM SHELL IN SOUND TOUCH ELASTOGRAPHY[J]. ULTRASOUND IN MEDICINE AND BIOLOGY,2019,45(3):710-719.
|
APA |
Zhang, Lei.,Xu, Jinfeng.,Wu, Huaiyu.,Liang, Weiyu.,Ye, Xiuqin.,...&Dong, Fajin.(2019).SCREENING BREAST LESIONS USING SHEAR MODULUS AND ITS 1-MM SHELL IN SOUND TOUCH ELASTOGRAPHY.ULTRASOUND IN MEDICINE AND BIOLOGY,45(3),710-719.
|
MLA |
Zhang, Lei,et al."SCREENING BREAST LESIONS USING SHEAR MODULUS AND ITS 1-MM SHELL IN SOUND TOUCH ELASTOGRAPHY".ULTRASOUND IN MEDICINE AND BIOLOGY 45.3(2019):710-719.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论