摘要
The aim of the study described here was to screen breast lesions using either or both shear modulus (G) and its 1-mm shell (S) in sound touch elastography through a retrospective study of 209 consecutive women with breast lesions. The ability of G and S data to differentiate between malignant and benign lesions was evaluated using the receiver operating characteristic (ROC) curve. The optimal cutoff point, sensitivity, specificity, positive likelihood ratio (LR+) and negative likelihood ratio (LR-) were calculated. Then, the parameters were pooled to determine the area under the summary receiver operating curve (AUSROC). The pooled sensitivity (PSen), pooled specificity (PSpe), pooled LR+ (PLR+), pooled LR- (PLR-) and diagnostic score (DS) were calculated. Pathologic examination results were used as the reference. In total, 209 patients with 155 benign and 54 malignant lesions were enrolled. For G(max), G(mean) and G(sd), the cutoff values were 35.15 kPa (p = 0.0001), 10.18 kPa (p = 0.0001) and 5.18 kPa (p = 0.0001), respectively. For S-max, S-mean and S-sd, the cutoff values were 40.94 kPa (p = 0.001), 13.12 kPa (p = 0.0001) and 7.97 kPa (p = 0.0001), respectively. There were no significant differences in G(min) and S-min between benign and malignant lesions. For the pooled six parameters, the PSen, PSpe, PLR+, PLR-, DS and AUSROC were 86% (95% confidence interval: 82%-89%), 82% (80%-85%), 4.90 (4.24-5.68), 0.17 (0.13-0.22), 3.36 (3.00-3.72) and 91% (88-93%), respectively. The G and S parameters of sound touch elastography could provide valuable data for the evaluation of breast lesions. Additionally, use of multiple parameters or combined use of the six parameters may be more effective in the evaluation of breast lesions. (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
关键词
相关链接[来源记录]
收录类别
SCI ; EI
语种
英语
学校署名
第一 ; 通讯
资助项目
Clinical Project of Shenzhen People's Hospital[SYLY201702]
WOS研究方向
Acoustics ; Radiology, Nuclear Medicine & Medical Imaging
WOS类目
Acoustics ; Radiology, Nuclear Medicine & Medical Imaging
WOS记录号
WOS:000457853400010
出版者
EI入藏号
20190206361262
EI主题词
Diagnosis ; Elastic moduli ; Parameter estimation ; Scattering parameters ; Shear strain ; Touch screens ; Ultrasonography
ESI学科分类
CLINICAL MEDICINE
来源库
Web of Science
引用统计
被引频次[WOS]:9
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/26308
专题南方科技大学第一附属医院
作者单位
1.Jinan Univ, Clin Coll 2, Southern Univ Sci & Technol,Shenzhen Peoples Hosp, Dept Ultrasound,Affiliated Hosp 1,Shenzhen Med Ul, Shenzhen 518020, Peoples R China
2.Guangzhou Med Univ, Guangzhou, Guangdong, Peoples R China
第一作者单位南方科技大学第一附属医院
通讯作者单位南方科技大学第一附属医院
第一作者的第一单位南方科技大学第一附属医院
推荐引用方式
GB/T 7714
Zhang, Lei,Xu, Jinfeng,Wu, Huaiyu,et al. SCREENING BREAST LESIONS USING SHEAR MODULUS AND ITS 1-MM SHELL IN SOUND TOUCH ELASTOGRAPHY[J]. ULTRASOUND IN MEDICINE AND BIOLOGY,2019,45(3):710-719.
APA
Zhang, Lei.,Xu, Jinfeng.,Wu, Huaiyu.,Liang, Weiyu.,Ye, Xiuqin.,...&Dong, Fajin.(2019).SCREENING BREAST LESIONS USING SHEAR MODULUS AND ITS 1-MM SHELL IN SOUND TOUCH ELASTOGRAPHY.ULTRASOUND IN MEDICINE AND BIOLOGY,45(3),710-719.
MLA
Zhang, Lei,et al."SCREENING BREAST LESIONS USING SHEAR MODULUS AND ITS 1-MM SHELL IN SOUND TOUCH ELASTOGRAPHY".ULTRASOUND IN MEDICINE AND BIOLOGY 45.3(2019):710-719.
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Zhang, Lei]的文章
[Xu, Jinfeng]的文章
[Wu, Huaiyu]的文章
百度学术
百度学术中相似的文章
[Zhang, Lei]的文章
[Xu, Jinfeng]的文章
[Wu, Huaiyu]的文章
必应学术
必应学术中相似的文章
[Zhang, Lei]的文章
[Xu, Jinfeng]的文章
[Wu, Huaiyu]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。