题名 | Advantages of contrast-enhanced transcranial doppler conducted via two-channels, compared to a single-channel |
作者 | |
通讯作者 | Guo, Yi |
发表日期 | 2019
|
发表期刊 | |
ISSN | 1940-5901
|
卷号 | 12期号:6页码:7082-7089 |
摘要 | The purpose of the current study was to evaluate the advantages of contrast-enhanced transcranial doppler (c-TCD) conducted via two-channel mode, compared to single-channel mode. The parallel test method of diagnostic testing was adopted. Two-channel c-TCD was conducted and interpreted via three different methods, comparing differences between the effects of conducting c-TCD via two-channel mode and single-channel (either left or right) mode. Conditions were set so that the appearance of microbubble signals in either channel was the golden diagnostic criteria for right to left shunts. Diagnostic sensitivity of single channel c-TCD mode was evaluated. Diagnostic consistencies and positive rates were compared between single-channel and two-channel modes. A total of 242 cases were enrolled in this study. Diagnostic sensitivities of left and right single channel mode were 77.46% and 76.06%, respectively, under a resting state. They were 95.31% and 96.88%, respectively, after the Valsalva maneuver (VM). Under a resting state, diagnostic consistencies were general between two-channel and left channel modes and between two-channel and right channel modes (Kappa value = 0.740, 0.724, respectively; P < 0.001). After VM, both diagnostic consistencies were good (Kappa value = 0.894, 0.928, repetitively; P < 0.001). After VM, although diagnostic consistencies were good, positive rates of two-channel c-TCD mode were significantly higher than those in both left and right single-channel c-TCD modes (79.34% vs. 75.62%, P = 0.004; 79.34% vs. 76.86%, P = 0.031; respectively). Two channel c-TCD mode had higher positive rates than single-channel mode, especially in patients with small right to left shunts or poor coordination of VM. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
; 通讯
|
资助项目 | Science and Technology Innovation Committee Project of Shenzhen[JCYJ201506051034-20338]
|
WOS研究方向 | Research & Experimental Medicine
|
WOS类目 | Medicine, Research & Experimental
|
WOS记录号 | WOS:000473289500059
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:0
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/26655 |
专题 | 南方科技大学第一附属医院 |
作者单位 | Jinan Univ, Dept Neurol, Affiliated Hosp 1,Shenzhen Peoples Hosp, Southern Univ Sci & Technol,Clin Med Coll 2, Shenzhen 518020, Guangdong, Peoples R China |
第一作者单位 | 南方科技大学第一附属医院 |
通讯作者单位 | 南方科技大学第一附属医院 |
第一作者的第一单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
He, Yitao,Zhang, Hui,Deng, Jian,et al. Advantages of contrast-enhanced transcranial doppler conducted via two-channels, compared to a single-channel[J]. International Journal of Clinical and Experimental Medicine,2019,12(6):7082-7089.
|
APA |
He, Yitao,Zhang, Hui,Deng, Jian,Yang, Miaojuan,Tang, Bingshan,&Guo, Yi.(2019).Advantages of contrast-enhanced transcranial doppler conducted via two-channels, compared to a single-channel.International Journal of Clinical and Experimental Medicine,12(6),7082-7089.
|
MLA |
He, Yitao,et al."Advantages of contrast-enhanced transcranial doppler conducted via two-channels, compared to a single-channel".International Journal of Clinical and Experimental Medicine 12.6(2019):7082-7089.
|
条目包含的文件 | 条目无相关文件。 |
|