中文版 | English
题名

Using big data from air quality monitors to evaluate indoor PM2.5 exposure in buildings: Case study in Beijing

作者
通讯作者Dong, ZhaoMin
发表日期
2018-09
DOI
发表期刊
ISSN
0269-7491
EISSN
1873-6424
卷号240页码:839-847
摘要
Due to time- and expense-consuming of conventional indoor PM2.5 (particulate matter with aerodynamic diameter of less than 2.5 mu m) sampling, the sample size in previous studies was generally small, which leaded to high heterogeneity in indoor PM2.5 exposure assessment. Based on 4403 indoor air monitors in Beijing, this study evaluated indoor PM2.5 exposure from 15th March 2016 to 14th March 2017. Indoor PM2.(5) concentration in Beijing was estimated to be 38.6 18.4 mu g/m(3). Specifically, the concentration in non-heating season was 34.9 +/- 15.8 mu g/m(3), which was 24% lower than that in heating season (46.1 +/- 21.2 mu g/m(3)). A significant correlation between indoor and ambient PM2.5 (p < 0.05) was evident with an infiltration factor of 0.21, and the ambient PM2.5 contributed approximately 52% and 42% to indoor PM2.5 for non-heating and heating seasons, respectively. Meanwhile, the mean indoor/outdoor (I/O) ratio was estimated to be 0.73 +/- 0.54. Finally, the adjusted PM2.5 exposure level integrating the indoor and outdoor impact was calculated to be 46.8 27.4 mu g/m(3), which was approximately 42% lower than estimation only relied on ambient PM2.5 concentration. This study is the first attempt to employ big data from commercial air monitors to evaluate indoor PM2.5 exposure and risk in Beijing, which may be instrumental to indoor PM2.5 pollution control. (C) 2018 Elsevier Ltd. All rights reserved.
关键词
相关链接[来源记录]
收录类别
SCI ; EI
语种
英语
学校署名
其他
资助项目
Beihang University[ZG216S1876]
WOS研究方向
Environmental Sciences & Ecology
WOS类目
Environmental Sciences
WOS记录号
WOS:000438322100090
出版者
EI入藏号
20182405302534
EI主题词
Air pollution control ; Air quality ; Heating ; Monitoring ; Quality control
EI分类号
Air Pollution Control:451.2 ; Data Processing and Image Processing:723.2 ; Quality Assurance and Control:913.3
ESI学科分类
ENVIRONMENT/ECOLOGY
来源库
Web of Science
引用统计
被引频次[WOS]:34
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/27308
专题工学院_环境科学与工程学院
作者单位
1.Beihang Univ, Sch Space & Environm, Beijing, Peoples R China
2.Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing 100191, Peoples R China
3.Inst Geog Sci & Nat Resources Res, State Key Lab Resources & Environm Informat Syst, Beijing, Peoples R China
4.South Univ Sci & Technol, Sch Environm Sci & Engn, Shenzhen 518055, Peoples R China
5.Kaiterra Ltd, Beijing, Peoples R China
推荐引用方式
GB/T 7714
Zuo, JinXing,Ji, Wei,Ben, Yujie,et al. Using big data from air quality monitors to evaluate indoor PM2.5 exposure in buildings: Case study in Beijing[J]. ENVIRONMENTAL POLLUTION,2018,240:839-847.
APA
Zuo, JinXing.,Ji, Wei.,Ben, Yujie.,Hassan, Muhammad Azher.,Fan, WenHong.,...&Dong, ZhaoMin.(2018).Using big data from air quality monitors to evaluate indoor PM2.5 exposure in buildings: Case study in Beijing.ENVIRONMENTAL POLLUTION,240,839-847.
MLA
Zuo, JinXing,et al."Using big data from air quality monitors to evaluate indoor PM2.5 exposure in buildings: Case study in Beijing".ENVIRONMENTAL POLLUTION 240(2018):839-847.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可 操作
Zuo-2018-Using big d(1659KB)----限制开放--
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Zuo, JinXing]的文章
[Ji, Wei]的文章
[Ben, Yujie]的文章
百度学术
百度学术中相似的文章
[Zuo, JinXing]的文章
[Ji, Wei]的文章
[Ben, Yujie]的文章
必应学术
必应学术中相似的文章
[Zuo, JinXing]的文章
[Ji, Wei]的文章
[Ben, Yujie]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。