题名 | Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses |
作者 | |
通讯作者 | Yang, Fangwei; Chen, Fei |
发表日期 | 2017
|
DOI | |
发表期刊 | |
ISSN | 2314-6133
|
EISSN | 2314-6141
|
摘要 | This study aimed to compare within-subject blood pressure (BP) variabilities from different measurement techniques. Cuff pressures from three repeated BP measurements were obtained from 30 normotensive and 30 hypertensive subjects. Automatic BPs were determined from the pulses with normalised peak amplitude larger than a threshold (0.5 for SBP, 0.7 for DBP, and 1.0 for MAP). They were also determined from cuff pressures associated with the above thresholds on a fitted curve polynomial curve of the oscillometric pulse peaks. Finally, the standard deviation (SD) of three repeats and its coefficient of variability (CV) were compared between the two automatic techniques. For the normotensive group, polynomial curve fitting significantly reduced SD of repeats from 3.6 to 2.5 mmHg for SBP and from 3.7 to 2.1 mmHg for MAP and reduced CV from 3.0% to 2.2% for SBP and from 4.3% to 2.4% for MAP (all P < 0.01). For the hypertensive group, SD of repeats decreased from 6.5 to 5.5 mmHg for SBP and from 6.7 to 4.2 mmHg for MAP, and CV decreased from 4.2% to 3.6% for SBP and from 5.8% to 3.8% for MAP (all P < 0.05). In conclusion, polynomial curve fitting of oscillometric pulses had the ability to reduce automatic BP measurement variability. |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 通讯
|
资助项目 | National Natural Science Foundation of China[61571213]
|
WOS研究方向 | Biotechnology & Applied Microbiology
; Research & Experimental Medicine
|
WOS类目 | Biotechnology & Applied Microbiology
; Medicine, Research & Experimental
|
WOS记录号 | WOS:000405792200001
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:2
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/29262 |
专题 | 工学院_电子与电气工程系 |
作者单位 | 1.Yiwu Cent Hosp, Dept Obstet & Gynecol, Yiwu, Peoples R China 2.Southern Univ Sci & Technol, Dept Elect & Elect Engn, Shenzhen, Peoples R China 3.Anglia Ruskin Univ, Hlth & Wellbeing Acad, Fac Med Sci, Chelmsford, Essex, England |
通讯作者单位 | 电子与电气工程系 |
推荐引用方式 GB/T 7714 |
Yang, Fangwei,Chen, Fei,Zhu, Mingping,et al. Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses[J]. Biomed Research International,2017.
|
APA |
Yang, Fangwei,Chen, Fei,Zhu, Mingping,Chen, Aiqing,&Zheng, Dingchang.(2017).Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses.Biomed Research International.
|
MLA |
Yang, Fangwei,et al."Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses".Biomed Research International (2017).
|
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | 操作 | |
5201069.pdf(1536KB) | -- | -- | 开放获取 | -- | 浏览 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论