摘要
Maintaining focus has been a critical but challenging issue in optical microscopy, particularly for microscopic imaging systems currently used in biomedical research. During live cell imaging, environmental temperature fluctuations and other factors contribute to the unavoidable focus drift. For single molecular imaging and super resolution, focus drift can be significant even over short durations. The current commercial and experimental solutions are either optically complicated, expensive, or with limited axial resolution. Here, we present a simple autofocus solution based on low cost solid state laser and imaging sensor. By improving the optical train design and using real-time data analysis, improvement in axial resolution by approximately two orders of magnitudes over the focal depth of microscope objectives can be achieved. This solution has been tested for prolonged live cell imaging for fast ramping up in environmental chamber temperature and large daily swing in room temperature. In addition, this system can be used to spatial-temporally measure the surface for three-dimensional cell culture and tissue engineering, with flexibility that exceeds commercially available systems. (C) 2013 AIP Publishing LLC.
相关链接[来源记录]
收录类别
SCI ; EI
语种
英语
学校署名
其他
资助项目
University of Hong Kong seed[104000978] ; University of Hong Kong seed[104001876]
WOS研究方向
Instruments & Instrumentation ; Physics
WOS类目
Instruments & Instrumentation ; Physics, Applied
WOS记录号
WOS:000329982000035
出版者
EI入藏号
20134917056822
EI主题词
Cell culture ; Environmental chambers ; Molecular imaging ; Solid state lasers ; Tissue engineering
EI分类号
Biomedical Engineering:461.1 ; Solid State Lasers:744.4
ESI学科分类
CHEMISTRY
来源库
Web of Science
引用统计
被引频次[WOS]:3
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/30294
专题南方科技大学
生命科学学院_生物系
作者单位
1.Univ Hong Kong, Dept Phys, Pokfulam, Hong Kong, Peoples R China
2.Univ Hong Kong, Dept Biochem, Pokfulam, Hong Kong, Peoples R China
3.South Univ Sci & Technol China, Shenzhen, Peoples R China
推荐引用方式
GB/T 7714
Li, Sihong,Cui, Xiaodong,Huang, Wei. High resolution autofocus for spatial temporal biomedical research[J]. REVIEW OF SCIENTIFIC INSTRUMENTS,2013,84(11).
APA
Li, Sihong,Cui, Xiaodong,&Huang, Wei.(2013).High resolution autofocus for spatial temporal biomedical research.REVIEW OF SCIENTIFIC INSTRUMENTS,84(11).
MLA
Li, Sihong,et al."High resolution autofocus for spatial temporal biomedical research".REVIEW OF SCIENTIFIC INSTRUMENTS 84.11(2013).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可 操作
Li-2013-High resolut(1229KB)----限制开放--
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Li, Sihong]的文章
[Cui, Xiaodong]的文章
[Huang, Wei]的文章
百度学术
百度学术中相似的文章
[Li, Sihong]的文章
[Cui, Xiaodong]的文章
[Huang, Wei]的文章
必应学术
必应学术中相似的文章
[Li, Sihong]的文章
[Cui, Xiaodong]的文章
[Huang, Wei]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。