中文版 | English
题名

Detection of Kidney Dysfunction through in Vivo Magnetic Resonance Imaging with Renal-Clearable Gadolinium Nanoprobes

作者
通讯作者Li,Kai
发表日期
2022-03-08
DOI
发表期刊
ISSN
0003-2700
EISSN
1520-6882
卷号94期号:9页码:4005-4011
摘要
Kidney dysfunction is a clinical syndrome that can subsequently result in lethal kidney failure. The exploration of emerging bioimaging contrast agents with translational potential is highly challenging for a feasible diagnosis of kidney dysfunction. Herein, a class of renal-clearable gadolinium nanoparticles (Gd@PEG NPs) with an ultrasmall size of ∼5 nm, good monodispersity, and T1 relaxivity are synthesized using mesoporous silica nanoparticles as the template. Assisted by such renal-clearable Gd@PEG NPs, the diagnosis of kidney dysfunction in a mice model with a damaged kidney has been achieved through in vivo noninvasive magnetic resonance imaging. As a result, this work paves the way to synthesize monodispersible ultrasmall Gd contrast agents, facilitating the exploration of translational strategies for an in vivo analysis of kidney dysfunction.
相关链接[Scopus记录]
收录类别
SCI ; EI
语种
英语
重要成果
NI论文
学校署名
第一 ; 通讯
资助项目
Ministry of Science and Technology of China[2020YFA0908900] ; National Natural Science Foundation of China[U21A2097] ; Department of Science and Technology of Guangdong Province["2019ZT08Y191","2019QN01Y640"] ; Shenzhen Key Laboratory of Smart Healthcare Engineering[ZDSYS20200811144003009] ; Shenzhen Science and Technology Program[KQTD20190929172743294]
WOS研究方向
Chemistry
WOS类目
Chemistry, Analytical
WOS记录号
WOS:000819810300031
出版者
EI入藏号
20221011748429
EI主题词
Gadolinium ; Mammals ; Nanomagnetics ; Silica nanoparticles ; Synthesis (chemical)
EI分类号
Rare Earth Metals:547.2 ; Magnetism: Basic Concepts and Phenomena:701.2 ; Imaging Techniques:746 ; Nanotechnology:761 ; Chemical Reactions:802.2
ESI学科分类
CHEMISTRY
Scopus记录号
2-s2.0-85125674609
来源库
Scopus
引用统计
被引频次[WOS]:13
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/328611
专题工学院_生物医学工程系
作者单位
1.Shenzhen Key Laboratory of Smart Healthcare Engineering,Department of Biomedical Engineering,Southern University of Science and Technology (SUSTech),Shenzhen,518055,China
2.Department of Mri Diagnosis,The Second Affiliated Hospital of Harbin Medical University,Harbin,Heilongjiang,150086,China
第一作者单位生物医学工程系
通讯作者单位生物医学工程系
第一作者的第一单位生物医学工程系
推荐引用方式
GB/T 7714
Wang,Jun,Zha,Menglei,Zhao,Hui,et al. Detection of Kidney Dysfunction through in Vivo Magnetic Resonance Imaging with Renal-Clearable Gadolinium Nanoprobes[J]. ANALYTICAL CHEMISTRY,2022,94(9):4005-4011.
APA
Wang,Jun,Zha,Menglei,Zhao,Hui,Yue,Wentong,Wu,Decheng,&Li,Kai.(2022).Detection of Kidney Dysfunction through in Vivo Magnetic Resonance Imaging with Renal-Clearable Gadolinium Nanoprobes.ANALYTICAL CHEMISTRY,94(9),4005-4011.
MLA
Wang,Jun,et al."Detection of Kidney Dysfunction through in Vivo Magnetic Resonance Imaging with Renal-Clearable Gadolinium Nanoprobes".ANALYTICAL CHEMISTRY 94.9(2022):4005-4011.
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Wang,Jun]的文章
[Zha,Menglei]的文章
[Zhao,Hui]的文章
百度学术
百度学术中相似的文章
[Wang,Jun]的文章
[Zha,Menglei]的文章
[Zhao,Hui]的文章
必应学术
必应学术中相似的文章
[Wang,Jun]的文章
[Zha,Menglei]的文章
[Zhao,Hui]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。