Bi-exponential fitting excluding b=0 data improves the scan-rescan stability of liver IVIM parameter measures and particularly so for the perfusion fraction

作者
通讯作者Wang, Yi Xiang J.
发表日期
2022-03-01
DOI
发表期刊
ISSN
2223-4292
EISSN
2223-4306
摘要
["Background: A prerequisite to translating intravoxel incoherent motion (IVIM) imaging into meaningful clinical applications is sufficient scan-rescan reproducibility. This study aims to confirm the hypothesis that IVIM data fitting by not using b=0 images will improve the stability of liver IVIM measurement.","Methods: Healthy volunteers' liver IVIM images were prospectively acquired using a 1.5-T magnet or a 3.0 T with 16 b-values. Repeatability study subjects were scanned twice during the same session, resulted in 35 paired scans for 35 subjects (11 men, mean age: 41.82 yrs, range: 32-60 yrs; 24 women, mean age: 42.67 yrs, range: 20-71 yrs). IVIM analysis was performed with full-fitting and segmented-fitting with a threshold b-value of 60 s/mm(2), and fitting started from b=0 s/mm(2) or from b=2 s/mm(2). Reproducibility study subjects were scanned and then rescanned with an interval of 5-18 days, resulted in 20 paired scans for 11 subjects (4 men, mean age: 26.25 yrs, range: 25-27 yrs; 7 women, mean age: 25.57 yrs, range: 24-27 yrs). IVIM analysis was performed with segmented-fitting with a threshold b-value of 50 s/mm(2), and fitting started from b=0 s/mm(2) or from b=3 s/mm(2).","Results: Fitting without b=0 data generally improved the repeatability and reproducibility for both PF and D-slow, and particularly so for PF. For with b=0 data segmented fitting repeatability, PF had within subject standard deviation of 0.019, bland-Atman 75% agreement limit of -31.52% to 28.35%, and ICC of 0.647, while these values were 0.009, -20.78% to 16.86%, and 0.837 for without b=0 analysis. Though the repeatability and reproducibility for D-fast generally also improved, they remained suboptimal. Measurement stability was better for repeatability than for reproducibility.","Conclusions: Scan-rescan repeatability and reproducibility of liver IVIM parameters can be improved by fitting without b=0 data, which is particularly so for PF."]
关键词
相关链接[来源记录]
收录类别
语种
英语
学校署名
其他
资助项目
Hong Kong GRF[14109218,14112521]
WOS研究方向
Radiology, Nuclear Medicine & Medical Imaging
WOS类目
Radiology, Nuclear Medicine & Medical Imaging
WOS记录号
WOS:000777336000001
出版者
来源库
Web of Science
引用统计
被引频次[WOS]:4
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/329540
专题南方科技大学第二附属医院
作者单位
1.Chinese Univ Hong Kong, Fac Med, Dept Imaging & Intervent Radiol, Hong Kong, Peoples R China
2.Southern Univ Sci & Technol, Natl Clin Res Ctr Infect Dis, Affiliated Hosp 2, Peoples Hosp Shenzhen 3,Dept Radiol, Shenzhen, Peoples R China
3.Nanjing Univ, Med Sch, Nanjing Drum Tower Hosp, Dept Radiol,Affiliated Hosp, Nanjing, Peoples R China
推荐引用方式
GB/T 7714
Zheng, Cun-Jing,Xiao, Ben-Heng,Huang, Hua,et al. Bi-exponential fitting excluding b=0 data improves the scan-rescan stability of liver IVIM parameter measures and particularly so for the perfusion fraction[J]. Quantitative Imaging in Medicine and Surgery,2022.
APA
Zheng, Cun-Jing,Xiao, Ben-Heng,Huang, Hua,Zhou, Nan,Yan, Tai-Yu,&Wang, Yi Xiang J..(2022).Bi-exponential fitting excluding b=0 data improves the scan-rescan stability of liver IVIM parameter measures and particularly so for the perfusion fraction.Quantitative Imaging in Medicine and Surgery.
MLA
Zheng, Cun-Jing,et al."Bi-exponential fitting excluding b=0 data improves the scan-rescan stability of liver IVIM parameter measures and particularly so for the perfusion fraction".Quantitative Imaging in Medicine and Surgery (2022).
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Zheng, Cun-Jing]的文章
[Xiao, Ben-Heng]的文章
[Huang, Hua]的文章
百度学术
百度学术中相似的文章
[Zheng, Cun-Jing]的文章
[Xiao, Ben-Heng]的文章
[Huang, Hua]的文章
必应学术
必应学术中相似的文章
[Zheng, Cun-Jing]的文章
[Xiao, Ben-Heng]的文章
[Huang, Hua]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。