题名 | Aortic Root Downward Movement as a Novel Method for Identification of an Adequately Performed Valsalva Maneuver to Detect Patent Foramen Ovale during Transesophageal Echocardiograph |
作者 | |
通讯作者 | Xu, Jinfeng; Liu, Yingying |
发表日期 | 2022-04-01
|
DOI | |
发表期刊 | |
EISSN | 2075-4418
|
卷号 | 12期号:4 |
摘要 | The Valsalva maneuver (VM) is the most sensitive auxiliary method for the detection of patent foramen ovale (PFO), but it is difficult to assess whether the maneuver is adequately performed during transesophageal echocardiography (TEE). In this study, we tried to use aortic root downward movement as a novel method for judging whether VM was adequate or not, and to evaluate whether this novel method can increase the sensitivity of detecting PFO. A total of 224 patients with clinically suspected PFO were enrolled in this study. These patients were injected with activated normal saline to detect the right-to-left shunt (RLS), in the following three conditions: contrast-enhanced transthoracic echocardiography under adequate VM (AVM cTTE), contrast-enhanced TEE under non-adequate VM (non-AVM cTEE), and cTEE under adequate VM (AVM cTEE). A novel method in which the aorta root moves downward (movement range >= 16 mm) in the cTEE judged whether AVM was performed. The PFO detection rate and sensitivity of AVM cTEE were better than that of non-AVM cTEE (detection rate: 108 PFOs [48.2%] vs. 86 PFOs [38.4%], p = 0.036; sensitivity: 100% vs. 79.6%). Among AVM cTTE, non-AVM cTEE, and AVM cTEE, the RLS grade evaluation results were inconsistent, with significant differences (p < 0.05). Non-AVM cTEE had RLS underestimation or false negatives. Compared with non-AVM cTEE, AVM cTEE and AVM cTTE had better consistency in evaluating PFO RLS (kappa value = 0.675). Aortic root downward movement could be used as a novel method for judging the effectiveness of VM, which is critical for the detection of PFO in cTEE. Concerning effectiveness and convenience, this method should be promoted during the clinical detection of PFO. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 其他
|
资助项目 | National Natural Science Foundation of China[81771841]
; Project of Innovation of the Science and Technology Commission of Shenzhen City[JCYJ20190807145609482]
|
WOS研究方向 | General & Internal Medicine
|
WOS类目 | Medicine, General & Internal
|
WOS记录号 | WOS:000785672000001
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:0
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/333478 |
专题 | 南方科技大学第一附属医院 |
作者单位 | 1.Jinan Univ, Shenzhen Peoples Hosp, Shenzhen Med Ultrasound Engn Ctr, Dept Ultrasound,Clin Med Coll 2, Shenzhen 518020, Peoples R China 2.Southern Univ Sci & Technol, Affiliated Hosp 1, Shenzhen 518020, Peoples R China |
推荐引用方式 GB/T 7714 |
Chen, Lixin,Sheng, Yuanyuan,Huang, Yuxiang,et al. Aortic Root Downward Movement as a Novel Method for Identification of an Adequately Performed Valsalva Maneuver to Detect Patent Foramen Ovale during Transesophageal Echocardiograph[J]. DIAGNOSTICS,2022,12(4).
|
APA |
Chen, Lixin.,Sheng, Yuanyuan.,Huang, Yuxiang.,Li, Jian.,Liu, Xiaohua.,...&Liu, Yingying.(2022).Aortic Root Downward Movement as a Novel Method for Identification of an Adequately Performed Valsalva Maneuver to Detect Patent Foramen Ovale during Transesophageal Echocardiograph.DIAGNOSTICS,12(4).
|
MLA |
Chen, Lixin,et al."Aortic Root Downward Movement as a Novel Method for Identification of an Adequately Performed Valsalva Maneuver to Detect Patent Foramen Ovale during Transesophageal Echocardiograph".DIAGNOSTICS 12.4(2022).
|
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | 操作 | |
10.3390@diagnostics1(2712KB) | -- | -- | 开放获取 | -- | 浏览 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论