题名 | Assessment of elastographic Q-analysis score combined with Prostate Imaging-Reporting and Data System (PI-RADS) based on transrectal ultrasound (TRUS)/multi-parameter magnetic resonance imaging (MP-MRI) fusion-guided biopsy in differentiating benign and malignant prostate |
作者 | |
通讯作者 | Xu, Jinfeng; Dong, Fajin |
发表日期 | 2022-03-01
|
DOI | |
发表期刊 | |
ISSN | 2223-4292
|
EISSN | 2223-4306
|
摘要 | ["Background: Magnetic resonance imaging (MRI) has advantages in the diagnosis of prostate diseases, but there is also overdiagnosis. We compensate for this with fusion imaging and elastography. In this study, we want to evaluate Elastographic Q-analysis score (EQS) combined with Prostate Imaging Reporting and Data System (PI-RADS), based on transrectal ultrasound (TRUS)/multi-parameter magnetic resonance imaging (MP-MRI) fusion biopsy in differentiating benign and malignant prostate lesions.","Methods: A total of 296 patients with 318 prostate lesions who underwent TRUS/MP-MRI fusion biopsy between October 2017 and October 2019 were retrospectively analysed. The performance of the EQS was evaluated on the sites of the suspicious areas of MP-MRI. The cut-off value of EQS was obtained according to receiver operating characteristic (ROC) curve, which was used to upgrade and downgrade the PI-RADS scores. The area under the curve (AUC), integrated discrimination improvement, and decision curve analysis were used to assess the new PI-RADS performance.","Results: In total, 318 MP-MRI suspicious prostate lesions (94 malignant vs. 224 benign lesions). The EQS optimal threshold was 1.85, and the AUC was 0.816. All cases were constructed three models by using 1.85 as the cut-off value: upgrade-PI-RADS, downgrade-PI-RADS and complex-PI-RADS. The AUC of PI-RADS, upgrade-PI-RADS, downgrade-PI-RADS and complex-PI-RADS were 0.869, 0.867, 0.872 and 0.873 respectively. The diagnostic coincidence rate of PI-RADS was increased from 0.667 to 0.874 by using strain elastography, among which the diagnostic rate of prostate cancer was increased from 0.557 to 0.806, and the diagnostic rate of non-prostate cancer was increased from 0.775 to 0.967. The integrated discrimination improvement indicated that downgrade-PI-RADS had a better diagnostic capability (P<0.05). The net benefit of all models, which downgrade-PI-RADS can maximize the net benefit value of patients by decision curve analysis.","Conclusions: The combination of PI-RADS and EQS with TRUS/MP-MRI fusion, particularly downgrade-PI-RADS, can reduce unnecessary biopsy procedures and prevent overdiagnosis."] |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
; 通讯
|
资助项目 | Commission of Science and Technology of Shenzhen[GJHZ20200731095401004]
|
WOS研究方向 | Radiology, Nuclear Medicine & Medical Imaging
|
WOS类目 | Radiology, Nuclear Medicine & Medical Imaging
|
WOS记录号 | WOS:000790591100001
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:2
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/334333 |
专题 | 南方科技大学第一附属医院 |
作者单位 | Southern Univ Sci & Technol, Affiliated Hosp 1, Dept Ultrasound,Shenzhen People Hosp, Clin Coll 2,Jinan Univ,Shenzhen Med Ultrasound En, 1017 Dongmen North Rd, Shenzhen 518020, Peoples R China |
第一作者单位 | 南方科技大学第一附属医院 |
通讯作者单位 | 南方科技大学第一附属医院 |
第一作者的第一单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
Tian, Hongtian,Ding, Zhimin,Wu, Huaiyu,et al. Assessment of elastographic Q-analysis score combined with Prostate Imaging-Reporting and Data System (PI-RADS) based on transrectal ultrasound (TRUS)/multi-parameter magnetic resonance imaging (MP-MRI) fusion-guided biopsy in differentiating benign and malignant prostate[J]. Quantitative Imaging in Medicine and Surgery,2022.
|
APA |
Tian, Hongtian.,Ding, Zhimin.,Wu, Huaiyu.,Yang, Keen.,Song, Di.,...&Dong, Fajin.(2022).Assessment of elastographic Q-analysis score combined with Prostate Imaging-Reporting and Data System (PI-RADS) based on transrectal ultrasound (TRUS)/multi-parameter magnetic resonance imaging (MP-MRI) fusion-guided biopsy in differentiating benign and malignant prostate.Quantitative Imaging in Medicine and Surgery.
|
MLA |
Tian, Hongtian,et al."Assessment of elastographic Q-analysis score combined with Prostate Imaging-Reporting and Data System (PI-RADS) based on transrectal ultrasound (TRUS)/multi-parameter magnetic resonance imaging (MP-MRI) fusion-guided biopsy in differentiating benign and malignant prostate".Quantitative Imaging in Medicine and Surgery (2022).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论