中文版 | English
题名

Left atrial reservoir and pump function after catheter ablation with persistent atrial fibrillation: a two-dimensional speckle tracking imaging study

作者
通讯作者Chen, Li-Xin
发表日期
2022-07-01
DOI
发表期刊
ISSN
0001-5385
EISSN
1784-973X
摘要
Objective By using ultrasound strain rate (SR) imaging to evaluate the left atrial (LA) reservoir and pump function after catheter ablation (CA) with persistent atrial fibrillation (PAF). Methods A total of 45 patients with PAF underwent echocardiography examination before and after ablation as well as during 6 months of follow-up. Peak SR was measured at each LA segment (septal, lateral, anterior, inferior and posterior) during systole (LAs) and late diastole (LAa). Results During 6 months after CA, 30 patients were free of atrial fibrillation recurrence (AFR). left atrial area index (LAAI), left atrial maximum volume index (LAVImax), and E/Ea were obviously higher in patients with before CA, left atrial ejection fraction (LAEF), SR-LAs were lower than in normal cases, the SR-LAa was disappeared. Shortly after ablation, SR-LAa was recovered, and SR-LAs was reduced compared to those at baseline. At midterm follow-up, LAEF and SR-LAs were still lower than the control group, and LAAI and LAVImax were higher. SR-LAa was recovered slowly over time, but still lower. Conclusion LA reservoir function was seriously damaged and LA pump function disappeared in patients with PAF. LA reservoir function impairment appeared shortly after ablation, it showed improvement at midterm follow-up, but some degree of damage to the LA reservoir and pump function was still present. Speckle tracking imaging is a feasible technique for the assessment of LA function in patients with PAF, which is a potentially valuable clinical tool to assist in the early detection of atrial remodelling and reverse remodelling.
关键词
相关链接[来源记录]
收录类别
语种
英语
学校署名
第一 ; 通讯
WOS研究方向
Cardiovascular System & Cardiology
WOS类目
Cardiac & Cardiovascular Systems
WOS记录号
WOS:000832905100001
出版者
来源库
Web of Science
引用统计
被引频次[WOS]:4
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/365016
专题南方科技大学第一附属医院
作者单位
1.Southern Univ Sci & Technol, Affiliated Hosp 1, Jinan Univ,Dept Ultrasound, Clin Med Coll 2,Shenzhen Peoples Hosp,Shenzhen Me, 1017 Dongmen North Rd, Shenzhen 518020, Peoples R China
2.Peking Univ, Dept Pain Management, Shenzhen Hosp, Shenzhen, Peoples R China
第一作者单位南方科技大学第一附属医院
通讯作者单位南方科技大学第一附属医院
第一作者的第一单位南方科技大学第一附属医院
推荐引用方式
GB/T 7714
Zhong, Xiao-Fang,Liu, Dong-Sheng,Zheng, Ying-Qi,et al. Left atrial reservoir and pump function after catheter ablation with persistent atrial fibrillation: a two-dimensional speckle tracking imaging study[J]. ACTA CARDIOLOGICA,2022.
APA
Zhong, Xiao-Fang.,Liu, Dong-Sheng.,Zheng, Ying-Qi.,Peng, Gui-Juan.,Sheng, Yuan-Yuan.,...&Liu, Ying-Ying.(2022).Left atrial reservoir and pump function after catheter ablation with persistent atrial fibrillation: a two-dimensional speckle tracking imaging study.ACTA CARDIOLOGICA.
MLA
Zhong, Xiao-Fang,et al."Left atrial reservoir and pump function after catheter ablation with persistent atrial fibrillation: a two-dimensional speckle tracking imaging study".ACTA CARDIOLOGICA (2022).
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Zhong, Xiao-Fang]的文章
[Liu, Dong-Sheng]的文章
[Zheng, Ying-Qi]的文章
百度学术
百度学术中相似的文章
[Zhong, Xiao-Fang]的文章
[Liu, Dong-Sheng]的文章
[Zheng, Ying-Qi]的文章
必应学术
必应学术中相似的文章
[Zhong, Xiao-Fang]的文章
[Liu, Dong-Sheng]的文章
[Zheng, Ying-Qi]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。