题名 | Left atrial reservoir and pump function after catheter ablation with persistent atrial fibrillation: a two-dimensional speckle tracking imaging study |
作者 | |
通讯作者 | Chen, Li-Xin |
发表日期 | 2022-07-01
|
DOI | |
发表期刊 | |
ISSN | 0001-5385
|
EISSN | 1784-973X
|
摘要 | Objective By using ultrasound strain rate (SR) imaging to evaluate the left atrial (LA) reservoir and pump function after catheter ablation (CA) with persistent atrial fibrillation (PAF). Methods A total of 45 patients with PAF underwent echocardiography examination before and after ablation as well as during 6 months of follow-up. Peak SR was measured at each LA segment (septal, lateral, anterior, inferior and posterior) during systole (LAs) and late diastole (LAa). Results During 6 months after CA, 30 patients were free of atrial fibrillation recurrence (AFR). left atrial area index (LAAI), left atrial maximum volume index (LAVImax), and E/Ea were obviously higher in patients with before CA, left atrial ejection fraction (LAEF), SR-LAs were lower than in normal cases, the SR-LAa was disappeared. Shortly after ablation, SR-LAa was recovered, and SR-LAs was reduced compared to those at baseline. At midterm follow-up, LAEF and SR-LAs were still lower than the control group, and LAAI and LAVImax were higher. SR-LAa was recovered slowly over time, but still lower. Conclusion LA reservoir function was seriously damaged and LA pump function disappeared in patients with PAF. LA reservoir function impairment appeared shortly after ablation, it showed improvement at midterm follow-up, but some degree of damage to the LA reservoir and pump function was still present. Speckle tracking imaging is a feasible technique for the assessment of LA function in patients with PAF, which is a potentially valuable clinical tool to assist in the early detection of atrial remodelling and reverse remodelling. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
; 通讯
|
WOS研究方向 | Cardiovascular System & Cardiology
|
WOS类目 | Cardiac & Cardiovascular Systems
|
WOS记录号 | WOS:000832905100001
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:4
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/365016 |
专题 | 南方科技大学第一附属医院 |
作者单位 | 1.Southern Univ Sci & Technol, Affiliated Hosp 1, Jinan Univ,Dept Ultrasound, Clin Med Coll 2,Shenzhen Peoples Hosp,Shenzhen Me, 1017 Dongmen North Rd, Shenzhen 518020, Peoples R China 2.Peking Univ, Dept Pain Management, Shenzhen Hosp, Shenzhen, Peoples R China |
第一作者单位 | 南方科技大学第一附属医院 |
通讯作者单位 | 南方科技大学第一附属医院 |
第一作者的第一单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
Zhong, Xiao-Fang,Liu, Dong-Sheng,Zheng, Ying-Qi,et al. Left atrial reservoir and pump function after catheter ablation with persistent atrial fibrillation: a two-dimensional speckle tracking imaging study[J]. ACTA CARDIOLOGICA,2022.
|
APA |
Zhong, Xiao-Fang.,Liu, Dong-Sheng.,Zheng, Ying-Qi.,Peng, Gui-Juan.,Sheng, Yuan-Yuan.,...&Liu, Ying-Ying.(2022).Left atrial reservoir and pump function after catheter ablation with persistent atrial fibrillation: a two-dimensional speckle tracking imaging study.ACTA CARDIOLOGICA.
|
MLA |
Zhong, Xiao-Fang,et al."Left atrial reservoir and pump function after catheter ablation with persistent atrial fibrillation: a two-dimensional speckle tracking imaging study".ACTA CARDIOLOGICA (2022).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论