题名 | Gait Deviation Correction Method for Gait Rehabilitation With a Lower Limb Exoskeleton Robot |
作者 | |
通讯作者 | Zhang,Zhimian; Leng,Yuquan |
发表日期 | 2022-08-01
|
DOI | |
发表期刊 | |
ISSN | 2576-3202
|
EISSN | 2576-3202
|
卷号 | 4期号:3页码:754-763 |
摘要 | Exoskeleton robots play an essential role in the gait rehabilitation of lower limbs in stroke patients. Existing lower limb exoskeleton robots commonly employ reference trajectories to perform gait rehabilitation training for patients. However, a significant gait deviation may occur between the gait trajectory of the wearer and the reference trajectory due to the following reasons. They are the physically flexible connection and the applied compliance control strategy between the wearer and the exoskeleton. This paper proposes a gait deviation correction method (GDCM) to decrease the gait deviation for lower limb exoskeleton robots. First, the gait curves of the exoskeleton and the wearer were obtained by using the clinical gait analysis (CGA) curve as a reference trajectory for the exoskeleton. Then, a gait correction model was trained by a database containing the CGA curve, the gait trajectory of both the exoskeleton and wearer obtained from 15 participants, and their body feature parameters such as height, weight, and hip-length. Finally, the gait correction model was introduced into the control system to modify the input trajectory of the exoskeleton. The experimental results showed that the gait trajectories of the wearer's hip and knee after correction were closer to the CGA curve than without modification. The minor gait trajectory deviation should lead to a better efficacy of the training with the robot if the reference trajectory is assumed to be optimal. |
关键词 | |
相关链接 | [Scopus记录] |
语种 | 英语
|
学校署名 | 通讯
|
Scopus记录号 | 2-s2.0-85135737428
|
来源库 | Scopus
|
全文链接 | https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9843940 |
引用统计 |
被引频次[WOS]:9
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/401632 |
专题 | 工学院_机械与能源工程系 |
作者单位 | 1.The School of Mechanical Engineering,Shenyang Jianzhu University,Shenyang,110168,China 2.The Department of Health Management Center,Qilu Hospital,Jinan,250062,China 3.The Department of Clinical Medicine,Shenzhen Milebot Robotics Company Ltd.,Shenzhen,518000,China 4.The Cheeloo College of Medicine,Shandong University,Jinan,250100,China 5.The Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems,Guangdong Prov. Key Laboratory of Human Augmentation and Rehabilitation Robotics in Universities,Department of Mechanical and Energy Engineering,Southern University of Science and Technology,Shenzhen,518055,China |
通讯作者单位 | 机械与能源工程系 |
推荐引用方式 GB/T 7714 |
Zhang,Shisheng,Guan,Xiao,Ye,Jing,et al. Gait Deviation Correction Method for Gait Rehabilitation With a Lower Limb Exoskeleton Robot[J]. IEEE Transactions on Medical Robotics and Bionics,2022,4(3):754-763.
|
APA |
Zhang,Shisheng,Guan,Xiao,Ye,Jing,Chen,Gong,Zhang,Zhimian,&Leng,Yuquan.(2022).Gait Deviation Correction Method for Gait Rehabilitation With a Lower Limb Exoskeleton Robot.IEEE Transactions on Medical Robotics and Bionics,4(3),754-763.
|
MLA |
Zhang,Shisheng,et al."Gait Deviation Correction Method for Gait Rehabilitation With a Lower Limb Exoskeleton Robot".IEEE Transactions on Medical Robotics and Bionics 4.3(2022):754-763.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论