中文版 | English
题名

Gait Deviation Correction Method for Gait Rehabilitation With a Lower Limb Exoskeleton Robot

作者
通讯作者Zhang,Zhimian; Leng,Yuquan
发表日期
2022-08-01
DOI
发表期刊
ISSN
2576-3202
EISSN
2576-3202
卷号4期号:3页码:754-763
摘要
Exoskeleton robots play an essential role in the gait rehabilitation of lower limbs in stroke patients. Existing lower limb exoskeleton robots commonly employ reference trajectories to perform gait rehabilitation training for patients. However, a significant gait deviation may occur between the gait trajectory of the wearer and the reference trajectory due to the following reasons. They are the physically flexible connection and the applied compliance control strategy between the wearer and the exoskeleton. This paper proposes a gait deviation correction method (GDCM) to decrease the gait deviation for lower limb exoskeleton robots. First, the gait curves of the exoskeleton and the wearer were obtained by using the clinical gait analysis (CGA) curve as a reference trajectory for the exoskeleton. Then, a gait correction model was trained by a database containing the CGA curve, the gait trajectory of both the exoskeleton and wearer obtained from 15 participants, and their body feature parameters such as height, weight, and hip-length. Finally, the gait correction model was introduced into the control system to modify the input trajectory of the exoskeleton. The experimental results showed that the gait trajectories of the wearer's hip and knee after correction were closer to the CGA curve than without modification. The minor gait trajectory deviation should lead to a better efficacy of the training with the robot if the reference trajectory is assumed to be optimal.
关键词
相关链接[Scopus记录]
语种
英语
学校署名
通讯
Scopus记录号
2-s2.0-85135737428
来源库
Scopus
全文链接https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9843940
引用统计
被引频次[WOS]:9
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/401632
专题工学院_机械与能源工程系
作者单位
1.The School of Mechanical Engineering,Shenyang Jianzhu University,Shenyang,110168,China
2.The Department of Health Management Center,Qilu Hospital,Jinan,250062,China
3.The Department of Clinical Medicine,Shenzhen Milebot Robotics Company Ltd.,Shenzhen,518000,China
4.The Cheeloo College of Medicine,Shandong University,Jinan,250100,China
5.The Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems,Guangdong Prov. Key Laboratory of Human Augmentation and Rehabilitation Robotics in Universities,Department of Mechanical and Energy Engineering,Southern University of Science and Technology,Shenzhen,518055,China
通讯作者单位机械与能源工程系
推荐引用方式
GB/T 7714
Zhang,Shisheng,Guan,Xiao,Ye,Jing,et al. Gait Deviation Correction Method for Gait Rehabilitation With a Lower Limb Exoskeleton Robot[J]. IEEE Transactions on Medical Robotics and Bionics,2022,4(3):754-763.
APA
Zhang,Shisheng,Guan,Xiao,Ye,Jing,Chen,Gong,Zhang,Zhimian,&Leng,Yuquan.(2022).Gait Deviation Correction Method for Gait Rehabilitation With a Lower Limb Exoskeleton Robot.IEEE Transactions on Medical Robotics and Bionics,4(3),754-763.
MLA
Zhang,Shisheng,et al."Gait Deviation Correction Method for Gait Rehabilitation With a Lower Limb Exoskeleton Robot".IEEE Transactions on Medical Robotics and Bionics 4.3(2022):754-763.
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Zhang,Shisheng]的文章
[Guan,Xiao]的文章
[Ye,Jing]的文章
百度学术
百度学术中相似的文章
[Zhang,Shisheng]的文章
[Guan,Xiao]的文章
[Ye,Jing]的文章
必应学术
必应学术中相似的文章
[Zhang,Shisheng]的文章
[Guan,Xiao]的文章
[Ye,Jing]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。