题名 | Investigation on the differences of hemodynamics in normal common carotid, subclavian, and common femoral arteries using the vector flow technique |
作者 | |
通讯作者 | Xu, Jinfeng; Gao, Wenjing; Dong, Fajin |
发表日期 | 2022-11-17
|
DOI | |
发表期刊 | |
ISSN | 2297-055X
|
卷号 | 9 |
摘要 | ObjectivesTo investigate the feasibility of the vector flow imaging (V Flow) technique to measure peripheral arterial hemodynamic parameters, including wall shear stress (WSS) and turbulence index (Tur) in healthy adults, and compare the results in different arteries. Materials and methodsFifty-two healthy adult volunteers were recruited in this study. The maximum and mean values of WSS, and the Tur values at early-systole, mid-systole, late-systole, and early diastole for total 156 normal peripheral arteries [common carotid arteries (CCA), subclavian arteries (SCA), and common femoral arteries (CFA)] were assessed using the V Flow technique. ResultsThe mean WSS values for CCA, SCA, and CFA were (1.66 +/- 0.68) Pa, (0.62 +/- 0.30) Pa, and (0.56 +/- 0.27) Pa, respectively. The mean Tur values for CCA, SCA, and CFA were (0.46 +/- 1.09%), (20.7 +/- 9.06%), and (24.63 +/- 17.66%), respectively. The CCA and SCA, as well as the CCA and CFA, showed statistically significant differences in the mean WSS and the mean Tur (P < 0.01). The mean Tur values had a negative correlation with the mean WSS; the correlation coefficient between log(Tur) and WSS is -0.69 (P < 0.05). ConclusionV Flow technique is a simple, practical, and feasible quantitative imaging approach for assessing WSS and Tur in peripheral arteries. It has the potential to be a useful tool for evaluating atherosclerotic plaques in peripheral arteries. The results provide a new quantitative foundation for future investigations into diverse arterial hemodynamic parameters. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
; 通讯
|
资助项目 | [GJHZ20200731095401004]
|
WOS研究方向 | Cardiovascular System & Cardiology
|
WOS类目 | Cardiac & Cardiovascular Systems
|
WOS记录号 | WOS:000892749800001
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:3
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/417075 |
专题 | 南方科技大学第一附属医院 |
作者单位 | 1.Jinan Univ, Southern Univ Sci & Technol, Shenzhen Peoples Hosp, Affiliated Hosp 1,Clin Med Coll 2,Dept Ultrasound, Shenzhen, Guangdong, Peoples R China 2.Shenzhen Mindray Biomed Elect Co Ltd, Shenzhen, Guangdong, Peoples R China |
第一作者单位 | 南方科技大学第一附属医院 |
通讯作者单位 | 南方科技大学第一附属医院 |
第一作者的第一单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
Song, Di,Liu, Mengmeng,Dong, Yinghui,et al. Investigation on the differences of hemodynamics in normal common carotid, subclavian, and common femoral arteries using the vector flow technique[J]. Frontiers in Cardiovascular Medicine,2022,9.
|
APA |
Song, Di.,Liu, Mengmeng.,Dong, Yinghui.,Hong, Shaofu.,Chen, Ming.,...&Dong, Fajin.(2022).Investigation on the differences of hemodynamics in normal common carotid, subclavian, and common femoral arteries using the vector flow technique.Frontiers in Cardiovascular Medicine,9.
|
MLA |
Song, Di,et al."Investigation on the differences of hemodynamics in normal common carotid, subclavian, and common femoral arteries using the vector flow technique".Frontiers in Cardiovascular Medicine 9(2022).
|