题名 | Thermal and moisture control performance of different mastectomy bras and external breast prostheses |
作者 | |
通讯作者 | Shin, Kristina |
发表日期 | 2019-10-22
|
DOI | |
发表期刊 | |
ISSN | 0040-5175
|
EISSN | 1746-7748
|
卷号 | 90页码:824-837 |
摘要 | This paper introduces a project involving a thermoregulation performance experiment design to evaluate the different responses of research subjects to a range of mastectomy bras and external breast prostheses. A set of newly designed heat-reduction mastectomy bras and prostheses were mix-matched with a set of conventional mastectomy bras and prostheses for the experiment. Four combinations of mastectomy bras and external breast prostheses were used: (a) Com A: conventional mastectomy bra and conventional prosthesis; (b) Com B: conventional mastectomy bra and heat-reduction prosthesis; (c) Com C: heat-reduction mastectomy bra and conventional prosthesis; and (d) Com D: heat-reduction mastectomy bra and heat-reduction prosthesis. Nine healthy male subjects (mean age: 31.9 +/- 5.9 y and mean under-bust circumference: 35.3 +/- 2.8 in) participated in this study in lieu of women who had undergone surgery for double mastectomy and were too self-conscious to expose their scars for sensor attachment. Eight sets of temperature and humidity sensors were placed between the surface of the skin and the prostheses and bra to measure the changes in both temperature and humidity data in a microclimate environment while the participants performed physical activity. The results showed that Com D demonstrated better thermal and moisture control, resulting in lower body temperature and lower humidity increment throughout the entire experiment. The study proved that the heat-reduction mastectomy bra and external breast prosthesis were effective in releasing the trapped heat and perspiration underneath the bra, and thus would provide a positive impact on clothing comfort and wearing experience for women who had undergone mastectomies. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 其他
|
资助项目 | Hong Kong Polytechnic University[B-Q21T]
|
WOS研究方向 | Materials Science
|
WOS类目 | Materials Science, Textiles
|
WOS记录号 | WOS:000492136700001
|
出版者 | |
EI入藏号 | 20194607673955
|
EI主题词 | Prosthetics
|
EI分类号 | Prosthetics:462.4
|
ESI学科分类 | MATERIALS SCIENCE
|
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:3
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/42127 |
专题 | 工学院_系统设计与智能制造学院 |
作者单位 | 1.Hong Kong Polytech Univ, Inst Text & Clothing, Hong Kong, Peoples R China 2.Southern Univ Sci & Technol, Sch Syst Design & Intelligent Mfg, Shenzhen, Guangdong, Peoples R China 3.Hong Kong Baptist Univ, Dr Stephen Hui Res Ctr Phys Recreat & Wellness, Hong Kong, Peoples R China |
推荐引用方式 GB/T 7714 |
Shin, Kristina,Leung, Kaoru,Han, Fred,et al. Thermal and moisture control performance of different mastectomy bras and external breast prostheses[J]. TEXTILE RESEARCH JOURNAL,2019,90:824-837.
|
APA |
Shin, Kristina,Leung, Kaoru,Han, Fred,&Jiao, Jiao.(2019).Thermal and moisture control performance of different mastectomy bras and external breast prostheses.TEXTILE RESEARCH JOURNAL,90,824-837.
|
MLA |
Shin, Kristina,et al."Thermal and moisture control performance of different mastectomy bras and external breast prostheses".TEXTILE RESEARCH JOURNAL 90(2019):824-837.
|
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | 操作 | |
10.1177_004051751988(1638KB) | -- | -- | 限制开放 | -- |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论