题名 | Evaluation of the Performance of the Ultrasound (US) Elastographic Q-Analysis Score Combined With the Prostate Imaging Reporting and Data System for Malignancy Risk Stratification in Prostate Nodules Based on Transrectal US-Magnetic Resonance Imaging Fusion Imaging |
作者 | |
通讯作者 | Xu, Jinfeng; Dong, Fajin |
发表日期 | 2019-11
|
DOI | |
发表期刊 | |
ISSN | 0278-4297
|
EISSN | 1550-9613
|
卷号 | 38期号:11页码:2991-2998 |
摘要 | Objectives This study retrospectively evaluated the prognostic performance of the ultrasound elastographic Q-analysis score (EQS) combined with the Prostate Imaging Reporting and Data System (PI-RADS) for malignancy risk stratification in prostate nodules based on transrectal ultrasound-magnetic resonance imaging fusion imaging. Methods Sixty-two patients who were suspected to have PCa between October 2017 and May 2018 in our hospital were retrospectively evaluated. The performance of the EQS and PI-RADS was evaluated by patients' receiver operating characteristic curves in differentiating malignant and benign prostate nodules. The combination of the EQS and PI-RADS methods for prostate imaging was evaluated. Results Sixty-two prostate nodules in 62 patients were included. All of the patients underwent biopsy; 29 cases were prostate cancer, and the rest were benign prostate lesions. Both the EQS and PI-RADS were significantly higher in malignant nodules than in benign nodules. The sensitivity, specificity, area under the curve, positive likelihood ratio, negative likelihood ratio, positive predictive value, negative predictive value, and Youden index of an EQS cutoff of 2.05 were 86.2%, 81.8%, 85.9%, 4.73, 0.169, 80.6%, 87.1%, and 68%, respectively. The corresponding numbers for a PI-RADS cutoff of 4 were 82.7%, 69.7%, 84.2%, 2.72, 0.25, 70.6%, 82.1%, and 52.4%. The "tandem" method had a higher diagnostic specificity (87.9%), positive likelihood ratio (6.55), and positive predictive value (85.1%). The "parallel" method had a higher diagnostic sensitivity (96.5%), negative likelihood ratio (0.06), and negative predictive value (95.2%). Conclusions both the EQS and PI-RADS had good diagnostic performance in differentiating between malignant and benign prostate lesions. The combination of the EQS and PI-RADS improved the diagnostic performance to a certain degree. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
; 通讯
|
资助项目 | Commission of Science and Technology of Shenzhen[JCYJ20170307095706970]
|
WOS研究方向 | Acoustics
; Radiology, Nuclear Medicine & Medical Imaging
|
WOS类目 | Acoustics
; Radiology, Nuclear Medicine & Medical Imaging
|
WOS记录号 | WOS:000491035700019
|
出版者 | |
EI入藏号 | 20195007811996
|
EI主题词 | Biopsy
; Calcium compounds
; Diseases
; Magnetic resonance imaging
; Risk assessment
; Silicon compounds
; Ultrasonics
|
EI分类号 | Medicine and Pharmacology:461.6
; Imaging Techniques:746
; Ultrasonic Waves:753.1
; Accidents and Accident Prevention:914.1
|
ESI学科分类 | CLINICAL MEDICINE
|
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:6
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/42196 |
专题 | 南方科技大学第一附属医院 |
作者单位 | Southern Univ Sci & Technol, Affiliated Hosp 1, Jinan Univ, Dept Ultrasound,Clin Coll 2, Shenzhen 518020, Peoples R China |
第一作者单位 | 南方科技大学第一附属医院 |
通讯作者单位 | 南方科技大学第一附属医院 |
第一作者的第一单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
Ding, Zhimin,Ye, Xiuqin,Zhang, Lei,et al. Evaluation of the Performance of the Ultrasound (US) Elastographic Q-Analysis Score Combined With the Prostate Imaging Reporting and Data System for Malignancy Risk Stratification in Prostate Nodules Based on Transrectal US-Magnetic Resonance Imaging Fusion Imaging[J]. JOURNAL OF ULTRASOUND IN MEDICINE,2019,38(11):2991-2998.
|
APA |
Ding, Zhimin.,Ye, Xiuqin.,Zhang, Lei.,Sun, Yu.,Ni, Zhipeng.,...&Dong, Fajin.(2019).Evaluation of the Performance of the Ultrasound (US) Elastographic Q-Analysis Score Combined With the Prostate Imaging Reporting and Data System for Malignancy Risk Stratification in Prostate Nodules Based on Transrectal US-Magnetic Resonance Imaging Fusion Imaging.JOURNAL OF ULTRASOUND IN MEDICINE,38(11),2991-2998.
|
MLA |
Ding, Zhimin,et al."Evaluation of the Performance of the Ultrasound (US) Elastographic Q-Analysis Score Combined With the Prostate Imaging Reporting and Data System for Malignancy Risk Stratification in Prostate Nodules Based on Transrectal US-Magnetic Resonance Imaging Fusion Imaging".JOURNAL OF ULTRASOUND IN MEDICINE 38.11(2019):2991-2998.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论