中文版 | English
题名

Deep learning-based automatic blood pressure measurement: evaluation of the effect of deep breathing, talking and arm movement

作者
通讯作者He, Peiyu; Zheng, Dingchang
发表日期
2019-11-17
DOI
发表期刊
ISSN
0785-3890
EISSN
1365-2060
卷号51期号:7-8页码:397-403
摘要
Objectives: It is clinically important to evaluate the performance of a newly developed blood pressure (BP) measurement method under different measurement conditions. This study aims to evaluate the performance of using deep learning-based method to measure BPs and BP change under non-resting conditions. Materials and methods: Forty healthy subjects were studied. Systolic and diastolic BPs (SBPs and DBPs) were measured under four conditions using deep learning and manual auscultatory method. The agreement between BPs determined by the two methods were analysed under different conditions. The performance of using deep learning-based method to measure BP changes was finally evaluated. Results: There were no significant BPs differences between two methods under all measurement conditions (all p > .1). SBP and DBP measured by deep learning method changed significantly in comparison with the resting condition: decreased by 2.3 and 4.2 mmHg with deeper breathing (both p < .05), increased by 3.6 and 6.4 mmHg with talking, and increased by 5.9 and 5.8 mmHg with arm movement (all p < .05). There were no significant differences in BP changes measured by two methods (all p > .4, except for SBP change with deeper breathing). Conclusion: This study demonstrated that the deep learning method could achieve accurate BP measurement under both resting and non-resting conditions.Key messages Accurate and reliable blood pressure measurement is clinically important. We evaluated the performance of our developed deep learning-based blood pressure measurement method under resting and non-resting measurement conditions. The deep learning-based method could achieve accurate BP measurement under both resting and non-resting measurement conditions.
关键词
相关链接[来源记录]
收录类别
语种
英语
学校署名
其他
WOS研究方向
General & Internal Medicine
WOS类目
Medicine, General & Internal
WOS记录号
WOS:000499041000007
出版者
ESI学科分类
CLINICAL MEDICINE
来源库
Web of Science
引用统计
被引频次[WOS]:9
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/50800
专题工学院_电子与电气工程系
作者单位
1.Sichuan Univ, Coll Elect & Informat Engn, Chengdu 610064, Sichuan, Peoples R China
2.Southern Univ Sci & Technol, Dept Elect & Elect Engn, Shenzhen, Guangdong, Peoples R China
3.Sichuan Univ, West China Hosp, Dept Cardiol, Chengdu, Sichuan, Peoples R China
4.Sichuan Univ, Coll Comp Sci, Chengdu, Sichuan, Peoples R China
5.Coventry Univ, Fac Hlth & Life Sci, Res Ctr Intelligent Healthcare, Coventry CV1 5FB, W Midlands, England
推荐引用方式
GB/T 7714
Pan, Fan,He, Peiyu,Chen, Fei,et al. Deep learning-based automatic blood pressure measurement: evaluation of the effect of deep breathing, talking and arm movement[J]. ANNALS OF MEDICINE,2019,51(7-8):397-403.
APA
Pan, Fan,He, Peiyu,Chen, Fei,Pu, Xiaobo,Zhao, Qijun,&Zheng, Dingchang.(2019).Deep learning-based automatic blood pressure measurement: evaluation of the effect of deep breathing, talking and arm movement.ANNALS OF MEDICINE,51(7-8),397-403.
MLA
Pan, Fan,et al."Deep learning-based automatic blood pressure measurement: evaluation of the effect of deep breathing, talking and arm movement".ANNALS OF MEDICINE 51.7-8(2019):397-403.
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Pan, Fan]的文章
[He, Peiyu]的文章
[Chen, Fei]的文章
百度学术
百度学术中相似的文章
[Pan, Fan]的文章
[He, Peiyu]的文章
[Chen, Fei]的文章
必应学术
必应学术中相似的文章
[Pan, Fan]的文章
[He, Peiyu]的文章
[Chen, Fei]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。