题名 | Dual spectral limited-angle CT imaging regularized by edge-preserving diffusion and smoothing |
作者 | |
发表日期 | 2023
|
DOI | |
发表期刊 | |
ISSN | 0895-3996
|
EISSN | 1095-9114
|
卷号 | 31期号:3页码:573-592 |
摘要 | Limited-angle CT scan is an effective way for nondestructive inspection of planar objects, and various methods have been proposed accordingly. When the scanned object contains high-absorption material, such as metal, existing methods may fail due to the beam hardening of X-rays. In order to overcome this problem, we adopt a dual spectral limited-angle CT scan and propose a corresponding image reconstruction algorithm, which takes the polychromatic property of the X-ray into consideration, makes basis material images free of beam hardening artifacts and metal artifacts, and then helps depress the limited-angle artifacts. Experimental results on both simulated PCB data and real data demonstrate the effectiveness of the proposed algorithm. |
关键词 | |
相关链接 | [Scopus记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 其他
|
资助项目 | National Natural Science Foundation of China["62271330","61971292","61871275","61827809","61771324"]
; National Key Research and Development Program of China[2020YFA0712200]
; Major Technologies R&D Program of Shenzhen[JSGGZD20220822095600001]
|
WOS研究方向 | Instruments & Instrumentation
; Optics
; Physics
|
WOS类目 | Instruments & Instrumentation
; Optics
; Physics, Applied
|
WOS记录号 | WOS:000987290400009
|
出版者 | |
Scopus记录号 | 2-s2.0-85159733278
|
来源库 | Scopus
|
引用统计 |
被引频次[WOS]:1
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/536751 |
专题 | 南方科技大学 |
作者单位 | 1.School of Mathematical Sciences,Capital Normal University,China 2.Beijing Advanced Innovation Center for Imaging Technology,Capital Normal University,China 3.Shenzhen National Applied Mathematics Center,Southern University of Science and Technology,Shenzhen,China |
推荐引用方式 GB/T 7714 |
Qin,Yanwei,Zhang,Yinghui,Lu,Xin,et al. Dual spectral limited-angle CT imaging regularized by edge-preserving diffusion and smoothing[J]. Journal of X-ray science and technology,2023,31(3):573-592.
|
APA |
Qin,Yanwei,Zhang,Yinghui,Lu,Xin,Zhao,Yunsong,&Zhao,Xing.(2023).Dual spectral limited-angle CT imaging regularized by edge-preserving diffusion and smoothing.Journal of X-ray science and technology,31(3),573-592.
|
MLA |
Qin,Yanwei,et al."Dual spectral limited-angle CT imaging regularized by edge-preserving diffusion and smoothing".Journal of X-ray science and technology 31.3(2023):573-592.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论