中文版 | English
题名

A pH-responsive T1-T2 dual-modal MRI contrast agent for cancer imaging

作者
通讯作者Wang,Zhongling; Tian,Leilei
发表日期
2022-12-01
DOI
发表期刊
EISSN
2041-1723
卷号13期号:1
摘要
Magnetic resonance imaging (MRI) is a non-invasive imaging technology to diagnose health conditions, showing the weakness of low sensitivity. Herein, we synthesize a contrast agent, SPIO@SiO@MnO, which shows decreased T and T contrast intensity in normal physiological conditions. In the acid environment of tumor or inflamed tissue, the manganese dioxide (MnO) layer decomposes into magnetically active Mn (T-weighted), and the T and T signals are sequentially recovered. In addition, both constrast quenching-activation degrees of T and T images can be accurately regulated by the silicon dioxide (SiO) intermediate layer between superparamagnetic iron oxide (SPIO) and MnO. Through the “dual-contrast enhanced subtraction” imaging processing technique, the contrast sensitivity of this MRI contrast agent is enhanced to a 12.3-time difference between diseased and normal tissue. Consequently, SPIO@SiO@MnO is successfully applied to trace the tiny liver metastases of approximately 0.5 mm and monitor tissue inflammation.
相关链接[Scopus记录]
收录类别
语种
英语
重要成果
NI论文
学校署名
第一 ; 通讯
资助项目
Science, Technology and Innovation Commission of Shenzhen Municipality[KQTD20170810111314625];
WOS记录号
WOS:000905505200009
Scopus记录号
2-s2.0-85144800505
来源库
Scopus
引用统计
被引频次[WOS]:36
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/536904
专题工学院_材料科学与工程系
作者单位
1.Department of Materials Science and Engineering,Southern University of Science and Technology,Shenzhen,Guangdong,518055,China
2.Department of Radiology,Shanghai General Hospital,School of Medicine,Shanghai Jiaotong University,Shanghai,200080,China
第一作者单位材料科学与工程系
通讯作者单位材料科学与工程系
第一作者的第一单位材料科学与工程系
推荐引用方式
GB/T 7714
Lu,Hongwei,Chen,An,Zhang,Xindan,et al. A pH-responsive T1-T2 dual-modal MRI contrast agent for cancer imaging[J]. Nature Communications,2022,13(1).
APA
Lu,Hongwei.,Chen,An.,Zhang,Xindan.,Wei,Zixiang.,Cao,Rong.,...&Tian,Leilei.(2022).A pH-responsive T1-T2 dual-modal MRI contrast agent for cancer imaging.Nature Communications,13(1).
MLA
Lu,Hongwei,et al."A pH-responsive T1-T2 dual-modal MRI contrast agent for cancer imaging".Nature Communications 13.1(2022).
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Lu,Hongwei]的文章
[Chen,An]的文章
[Zhang,Xindan]的文章
百度学术
百度学术中相似的文章
[Lu,Hongwei]的文章
[Chen,An]的文章
[Zhang,Xindan]的文章
必应学术
必应学术中相似的文章
[Lu,Hongwei]的文章
[Chen,An]的文章
[Zhang,Xindan]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。