题名 | Autocorrelation analysis-based OCT velocimetry for axial blood flow velocity imaging of the cerebral capillary network |
作者 | |
通讯作者 | Tang,Jianbo |
发表日期 | 2023-07-01
|
DOI | |
发表期刊 | |
ISSN | 0008-5472
|
EISSN | 1538-7445
|
卷号 | 48期号:13页码:3599-3602 |
摘要 | The accurate measurement of blood flow velocity in the capillary network is challenging due to the small size of the vessels and the slow flow of red blood cells (RBCs) within the vessel. Here, we introduce an autocorrelation analysis-based optical coherence tomography (OCT) method that takes less acquisition time to measure the axial blood flow velocity in the capillary network. The axial blood flow velocity was obtained from the phase change in the decorrelation period of the first-order field autocorrelation function (g) of the OCT field data, which was acquired with M-mode acquisition (repeated A-scans). The rotation center of g in the complex plane was first re-centralized to the origin, then the phase change due to the movement of RBCs was extracted in the g decorrelation period which is usually 0.2–0.5 ms. In phantom experiments, the results suggest that the proposed method could accurately measure the axial speed with a wide range of 0.5–15 mm/s. We further tested the method on living animals. Compared with the phase-resolved Doppler optical coherence tomography (pr-DOCT), the proposed method can obtain robust axial velocity measurements with more than five times shorter acquisition time. |
相关链接 | [Scopus记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
; 通讯
|
资助项目 | Shenzhen Graduate School, Peking University[1406001];Shenzhen Graduate School, Peking University[2021031616];Guangdong Science and Technology Department[2022A151];Guangdong Provincial Key Laboratory of Urology[2022B1212010003];Guangdong Science and Technology Department[5011984];National Natural Science Foundation of China[62220106006];National Natural Science Foundation of China[62275116];
|
WOS研究方向 | Optics
|
WOS类目 | Optics
|
WOS记录号 | WOS:001033631600002
|
出版者 | |
ESI学科分类 | CLINICAL MEDICINE
|
Scopus记录号 | 2-s2.0-85164234158
|
来源库 | Scopus
|
引用统计 |
被引频次[WOS]:0
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/559890 |
专题 | 工学院_生物医学工程系 |
作者单位 | Guangdongs Provincial Key Laboratory of Advanced Biomaterials,Department of Biomedical Engineering,Southern University of Science and Technology,Shenzhen,Guangdong,518055,China |
第一作者单位 | 生物医学工程系 |
通讯作者单位 | 生物医学工程系 |
第一作者的第一单位 | 生物医学工程系 |
推荐引用方式 GB/T 7714 |
Guo,Xiangsen,Ren,Guangyuan,Tang,Jianbo. Autocorrelation analysis-based OCT velocimetry for axial blood flow velocity imaging of the cerebral capillary network[J]. Cancer Research,2023,48(13):3599-3602.
|
APA |
Guo,Xiangsen,Ren,Guangyuan,&Tang,Jianbo.(2023).Autocorrelation analysis-based OCT velocimetry for axial blood flow velocity imaging of the cerebral capillary network.Cancer Research,48(13),3599-3602.
|
MLA |
Guo,Xiangsen,et al."Autocorrelation analysis-based OCT velocimetry for axial blood flow velocity imaging of the cerebral capillary network".Cancer Research 48.13(2023):3599-3602.
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论