题名 | Feasibility and reproducibility of semi-automated longitudinal strain analysis: a comparative study with conventional manual strain analysis |
作者 | |
通讯作者 | Xu, Jin-feng; Liu, Ying-ying; Chen, Li-xin |
发表日期 | 2023-07-19
|
DOI | |
发表期刊 | |
EISSN | 1476-7120
|
卷号 | 21期号:1 |
摘要 | ["Background Conventional approach to myocardial strain analysis relies on a software designed for the left ventricle (LV) which is complex and time-consuming and is not specific for right ventricular (RV) and left atrial (LA) assessment. This study compared this conventional manual approach to strain evaluation with a novel semi-automatic analysis of myocardial strain, which is also chamber-specific.","Methods Two experienced observers used the AutoStrain software and manual QLab analysis to measure the LV, RV and LA strains in 152 healthy volunteers. Fifty cases were randomly selected for timing evaluation.","Results No significant differences in LV global longitudinal strain (LVGLS) were observed between the two methods (-21.0% +/- 2.5% vs. -20.8% +/- 2.4%, p = 0.230). Conversely, RV longitudinal free wall strain (RVFWS) and LA longitudinal strain during the reservoir phase (LASr) measured by the semi-automatic software differed from the manual analysis (RVFWS: -26.4% +/- 4.8% vs. -31.3% +/- 5.8%, p < 0.001; LAS: 48.0% +/- 10.0% vs. 37.6% +/- 9.9%, p < 0.001). Bland-Altman analysis showed a mean error of 0.1%, 4.9%, and 10.5% for LVGLS, RVFWS, and LASr, respectively, with limits of agreement of-2.9,2.6%, -8.1,17.9%, and -12.3,33.3%, respectively. The semi-automatic method had a significantly shorter strain analysis time compared with the manual method.","Conclusions The novel semi-automatic strain analysis has the potential to improve efficiency in measurement of longitudinal myocardial strain. It shows good agreement with manual analysis for LV strain measurement."] |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 通讯
|
资助项目 | National Natural Science Foundation of China[82102041]
; Project of Innovation of the Science and Technology Commission of Shenzhen["JCYJ20190807145609482","JCYJ20210324113804013"]
|
WOS研究方向 | Cardiovascular System & Cardiology
|
WOS类目 | Cardiac & Cardiovascular Systems
|
WOS记录号 | WOS:001032518400001
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:6
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/583049 |
专题 | 南方科技大学第一附属医院 |
作者单位 | 1.Jinan Univ, Shenzhen Peoples Hosp, Shenzhen Med Ultrasound Engn Ctr, Dept Ultrasound,Clin Med Coll 2, Shenzhen 518020, Peoples R China 2.Southern Univ Sci & Technol, Affiliated Hosp 1, Shenzhen 518020, Peoples R China |
第一作者单位 | 南方科技大学第一附属医院 |
通讯作者单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
Peng, Gui-juan,Luo, Shu-yu,Zhong, Xiao-fang,et al. Feasibility and reproducibility of semi-automated longitudinal strain analysis: a comparative study with conventional manual strain analysis[J]. CARDIOVASCULAR ULTRASOUND,2023,21(1).
|
APA |
Peng, Gui-juan.,Luo, Shu-yu.,Zhong, Xiao-fang.,Lin, Xiao-xuan.,Zheng, Ying-qi.,...&Chen, Li-xin.(2023).Feasibility and reproducibility of semi-automated longitudinal strain analysis: a comparative study with conventional manual strain analysis.CARDIOVASCULAR ULTRASOUND,21(1).
|
MLA |
Peng, Gui-juan,et al."Feasibility and reproducibility of semi-automated longitudinal strain analysis: a comparative study with conventional manual strain analysis".CARDIOVASCULAR ULTRASOUND 21.1(2023).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论