题名 | Modified graphene oxide/Nafion composite humidity sensor and its linear response to the relative humidity |
作者 | |
通讯作者 | Wang,Fei |
发表日期 | 2018-03-01
|
DOI | |
发表期刊 | |
ISSN | 0925-4005
|
卷号 | 257页码:372-381 |
摘要 | Graphene oxide (GO) and its derivatives have been applied to the humidity sensing area in recent years due to its abundant hydrophilic functional groups, and proved to be ultrasensitive to the humidity changing. But the stability of the sensors is always an obstacle to their application. Besides, the long-term linearity is seldom studied. In this work, diamine modified GO (MGO) has been synthesized and mixed with Nafion polymer to form a hybrid film, and applied to the humidity sensors. We have applied two measurement methods by either fitting of the impedance spectra to extract charge transfer resistance (R) or measurement of the impedance under a certain frequency, to evaluate the response to the relative humidity (RH). Both MGO and its composite show good sensitivity to the RH under the two testing methods The R shows good linearity at the full testing RH range even after two months, while the impedance under a certain frequency can't keep the linear response to the RH after certain period of time. The addition of Nafion decreases the R and increases the sensitivity of MGO based sensor. Linearity of the sensor is improved by the combination of MGO and Nafion. Long-term testing results show the linearity of the composite sensors changes over time but always keeps a better linearity than the pure MGO sensor. |
关键词 | |
相关链接 | [Scopus记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 通讯
|
WOS记录号 | WOS:000418868700043
|
EI入藏号 | 20174504382625
|
EI主题词 | Charge transfer
; Testing
; Humidity sensors
; Graphene
|
EI分类号 | Meteorological Instrumentation:443.2
; Nanotechnology:761
; Chemical Reactions:802.2
; Chemical Products Generally:804
|
ESI学科分类 | CHEMISTRY
|
Scopus记录号 | 2-s2.0-85032948302
|
来源库 | Scopus
|
引用统计 |
被引频次[WOS]:77
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/64248 |
专题 | 工学院_电子与电气工程系 理学院_化学系 |
作者单位 | 1.Department of Electrical and Electronic Engineering,Southern University of Science and Technology,Shenzhen,518055,China 2.Shenzhen Key Laboratory of 3rd Generation Semiconductor Devices,Shenzhen,518055,China 3.Department of Chemistry,Southern University of Science and Technology,Shenzhen,518055,China 4.State Key Lab. of Transducer Technology,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,Shanghai,200050,China |
第一作者单位 | 电子与电气工程系 |
通讯作者单位 | 电子与电气工程系 |
第一作者的第一单位 | 电子与电气工程系 |
推荐引用方式 GB/T 7714 |
Leng,Xiaohui,Luo,Dan,Xu,Zongxiang,et al. Modified graphene oxide/Nafion composite humidity sensor and its linear response to the relative humidity[J]. SENSORS AND ACTUATORS B-CHEMICAL,2018,257:372-381.
|
APA |
Leng,Xiaohui,Luo,Dan,Xu,Zongxiang,&Wang,Fei.(2018).Modified graphene oxide/Nafion composite humidity sensor and its linear response to the relative humidity.SENSORS AND ACTUATORS B-CHEMICAL,257,372-381.
|
MLA |
Leng,Xiaohui,et al."Modified graphene oxide/Nafion composite humidity sensor and its linear response to the relative humidity".SENSORS AND ACTUATORS B-CHEMICAL 257(2018):372-381.
|
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | 操作 | |
Sensor and Actuators(4659KB) | -- | -- | 限制开放 | -- |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论