摘要
Carcinoembryonic antigen (CEACAM5), as a broad-spectrum tumor biomarker, plays a crucial role in analyzing the therapeutic efficacy and progression of cancer. Herein, we propose a novel biosensor based on specklegrams of tapered multimode fiber (MMF) and two-dimensional convolutional neural networks (2D-CNNs) for the detection of CEACAM5. The microfiber is modified with CEA antibodies to specifically recognize antigens. The biosensor utilizes the interference effect of tapered MMF to generate highly sensitive specklegrams in response to different CEACAM5 concentrations. A zero mean normalized cross-correlation (ZNCC) function is explored to calculate the image matching degree of the specklegrams. Profiting from the extremely high detection limit of the speckle sensor, variations in the specklegrams of antibody concentrations from 1 to 1000 ng/mL are measured in the experiment. The surface sensitivity of the biosensor is 0.0012 (ng/mL) within a range of 1 to 50 ng/mL. Moreover, a 2D-CNN was introduced to solve the problem of nonlinear detection surface sensitivity variation in a large dynamic range, and in the search for image features to improve evaluation accuracy, achieving more accurate CEACAM5 monitoring, with a maximum detection error of 0.358%. The proposed fiber specklegram biosensing scheme is easy to implement and has great potential in analyzing the postoperative condition of patients.
关键词
相关链接[Scopus记录]
收录类别
SCI ; EI
语种
英语
学校署名
第一 ; 通讯
Scopus记录号
2-s2.0-85183490769
来源库
Scopus
引用统计
被引频次[WOS]:2
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/701746
专题工学院_电子与电气工程系
作者单位
1.Department of Electronic and Electrical Engineering,Southern University of Science and Technology,Shenzhen,518055,China
2.Department of Applied Physics,Hong Kong Polytechnic University,Hongkong,999077,China
3.Department of Electrical and Computer Engineering,Faculty of Science and Technology,University of Macau,999078,Macao
4.Peng Cheng Laboratory,Shenzhen,518055,China
第一作者单位电子与电气工程系
通讯作者单位电子与电气工程系
第一作者的第一单位电子与电气工程系
推荐引用方式
GB/T 7714
Liu,Yuhui,Lin,Weihao,Zhao,Fang,et al. A Multimode Microfiber Specklegram Biosensor for Measurement of CEACAM5 through AI Diagnosis[J]. Biosensors,2024,14(1).
APA
Liu,Yuhui.,Lin,Weihao.,Zhao,Fang.,Liu,Yibin.,Sun,Junhui.,...&Shao,Liyang.(2024).A Multimode Microfiber Specklegram Biosensor for Measurement of CEACAM5 through AI Diagnosis.Biosensors,14(1).
MLA
Liu,Yuhui,et al."A Multimode Microfiber Specklegram Biosensor for Measurement of CEACAM5 through AI Diagnosis".Biosensors 14.1(2024).
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Liu,Yuhui]的文章
[Lin,Weihao]的文章
[Zhao,Fang]的文章
百度学术
百度学术中相似的文章
[Liu,Yuhui]的文章
[Lin,Weihao]的文章
[Zhao,Fang]的文章
必应学术
必应学术中相似的文章
[Liu,Yuhui]的文章
[Lin,Weihao]的文章
[Zhao,Fang]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。