中文版 | English
题名

A method for estimating the contact area of a dual-mobility total hip prosthesis

作者
通讯作者Hidayat,Taufiq
发表日期
2024
DOI
发表期刊
EISSN
2158-3226
卷号14期号:1
摘要
The term “contact area” refers to the total surface area of two entities in direct physical touch. When discussing an artificial hip joint, “contact area” refers to the surface area of contact between the components of the artificial hip joint (ball and cup) positioned inside the patient. Several methods can be used to figure out the contact area of an artificial hip joint, such as finite element analysis and traditional experiments on contact mechanics with hip joint simulators. The contact area in an artificial hip joint ensures load distribution. For optimal and long-term performance, the prosthetic hip joint’s contact area must be well understood for design, fitting, and monitoring. This study presented a novel method to estimate the liner surface contact area due to interaction contact in the artificial hip joint using a computer-aided design (CAD) program. This study also contrasted numerical approaches utilizing computer-aided engineering software and theoretical predictions based on Hertz theory with three-dimensional processes using CAD software to determine the contact area in the inner liner. There were no significant discrepancies in the outcomes of the three approaches.
相关链接[Scopus记录]
收录类别
SCI ; EI
语种
英语
学校署名
其他
Scopus记录号
2-s2.0-85182735862
来源库
Scopus
引用统计
被引频次[WOS]:2
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/701845
专题工学院_力学与航空航天工程系
工学院
作者单位
1.Department of Mechanical Engineering,Faculty of Engineering,Universitas Muria Kudus,Kudus,West Java,59324,Indonesia
2.Department of Mechanical Engineering,Faculty of Engineering,Universitas Diponegoro,Semarang,Central Java,50275,Indonesia
3.Department of Mechanics and Aerospace Engineering,College of Engineering,Southern University of Science and Technology,Shenzhen,Guangdong,518055,China
4.Undip Biomechanics Engineering and Research Centre (UBM-ERC),Universitas Diponegoro,Semarang,Central Java,50275,Indonesia
5.Department of Mechanical Engineering,Politeknik Negeri Semarang,Semarang,Central Java,50275,Indonesia
6.Department of Aeronautical and Automobile Engineering,Manipal Institute of Technology,Manipal Academy of Higher Education,Manipal,Karnataka,576104,India
7.Center for Biomechanics Biomaterials Biomechatronics and Biosignal Processing (CBIOM3S),Universitas Diponegoro,Semarang,Central Java,50275,Indonesia
推荐引用方式
GB/T 7714
Hidayat,Taufiq,Ammarullah,Muhammad Imam,Saputra,Eko,et al. A method for estimating the contact area of a dual-mobility total hip prosthesis[J]. AIP Advances,2024,14(1).
APA
Hidayat,Taufiq.,Ammarullah,Muhammad Imam.,Saputra,Eko.,Lamura,M. Danny Pratama.,Chethan,Chethan N..,...&Jamari,J..(2024).A method for estimating the contact area of a dual-mobility total hip prosthesis.AIP Advances,14(1).
MLA
Hidayat,Taufiq,et al."A method for estimating the contact area of a dual-mobility total hip prosthesis".AIP Advances 14.1(2024).
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Hidayat,Taufiq]的文章
[Ammarullah,Muhammad Imam]的文章
[Saputra,Eko]的文章
百度学术
百度学术中相似的文章
[Hidayat,Taufiq]的文章
[Ammarullah,Muhammad Imam]的文章
[Saputra,Eko]的文章
必应学术
必应学术中相似的文章
[Hidayat,Taufiq]的文章
[Ammarullah,Muhammad Imam]的文章
[Saputra,Eko]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论