中文版 | English
题名

An array of femtoliter wells for sensitive detection of copper using click chemistry

作者
通讯作者Wang,Dou
发表日期
2024-07-01
DOI
发表期刊
ISSN
0039-9140
卷号274
摘要
Sensitive detection of copper ion (Cu), which is of great importance for environmental pollution and human health, is crucial. In this study, we present a highly sensitive method for measuring Cu in an array of femtoliter wells. In brief, magnetic beads (MBs) modified with alkyne groups were bound to the azide groups of biotin-PEG3-azide (bio-PEG-N) via Cu-catalyzed click chemistry. Cu in the click chemistry reaction was generated by reducing Cu with sodium ascorbate. Following the ligation, the surface of the MBs was modified with biotin, which could be labeled with streptavidin-β-galactosidase (SβG). The MBs complex was then suspended in β-galactosidase substrate fluorescein-di-β-D-galactopyranoside (FDG), and loaded into the array of femtoliter wells. The MBs sank into the wells due to gravity, and the resulting fluorescent product, generated from the reaction between SβG on the surface of the MBs and FDG, was confined within the wells. The number of fluorescent wells increased with higher Cu concentrations. The bright-field and fluorescent images of the wells were acquired using an inverted fluorescent microscope. The detection limit of this assay for Cu was 1 nM without signal amplification, which was 10 times lower than that of traditional fluorescence detection assays.
关键词
相关链接[Scopus记录]
收录类别
SCI ; EI
语种
英语
学校署名
通讯
EI入藏号
20241315823950
EI主题词
Coenzymes ; Copper ; Fluorescence ; Metal ions ; Synthesis (chemical)
EI分类号
Metallurgy:531.1 ; Copper:544.1 ; Microfluidics:632.5.1 ; Light/Optics:741.1 ; Chemical Reactions:802.2
ESI学科分类
CHEMISTRY
Scopus记录号
2-s2.0-85188683967
来源库
Scopus
引用统计
被引频次[WOS]:1
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/741069
专题工学院_生物医学工程系
作者单位
1.College of Health Science and Environmental Engineering,Shenzhen Technology University,Shenzhen,3002 Lantian Road, Pingshan District, Guangdong,518118,China
2.The Key Laboratory of Environmental Pollution Monitoring and Disease Control,Ministry of Education,School of Public Health,Guizhou Medical University,Guiyang,Guizhou,550025,China
3.Shenzhen Key Laboratory of Smart Healthcare Engineering,Department of Biomedical Engineering,Southern University of Science and Technology,Shenzhen,No. 1088, Xueyuan Rd., Xili, Nanshan District, Guangdong,518055,China
通讯作者单位生物医学工程系
推荐引用方式
GB/T 7714
Ge,Chenchen,Chen,Xiong,Wang,Dou. An array of femtoliter wells for sensitive detection of copper using click chemistry[J]. Talanta,2024,274.
APA
Ge,Chenchen,Chen,Xiong,&Wang,Dou.(2024).An array of femtoliter wells for sensitive detection of copper using click chemistry.Talanta,274.
MLA
Ge,Chenchen,et al."An array of femtoliter wells for sensitive detection of copper using click chemistry".Talanta 274(2024).
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Ge,Chenchen]的文章
[Chen,Xiong]的文章
[Wang,Dou]的文章
百度学术
百度学术中相似的文章
[Ge,Chenchen]的文章
[Chen,Xiong]的文章
[Wang,Dou]的文章
必应学术
必应学术中相似的文章
[Ge,Chenchen]的文章
[Chen,Xiong]的文章
[Wang,Dou]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。