题名 | CRISPR-HOLMES-based NAD+ detection |
作者 | |
通讯作者 | Xu, Yong; Chen, Yijian; Wang, Jin |
发表日期 | 2024-03-25
|
DOI | |
发表期刊 | |
ISSN | 2296-4185
|
卷号 | 12 |
摘要 | Studies have indicated that the intracellular nicotinamide adenine dinucleotide (NAD+) level is associated with the occurrence and development of many diseases. However, traditional nicotinamide adenine dinucleotide (NAD+) detection techniques are time-consuming and may require large and expensive instruments. We recently found that the clustered regularly interspaced short palindromic repeat (CRISPR)-Cas12a protein can be inactivated by AcrVA5-mediated acetylation and reactivated by CobB, using NAD+ as the co-factor. Therefore, in this study, we created a CRISPR-Cas12a-based one-step HOLMES(NAD+) system for rapid and convenient NAD+ detection with the employment of both acetylated Cas12a and CobB. In HOLMES(NAD+), acetylated Cas12a loses its trans-cleavage activities and can be reactivated by CobB in the presence of NAD+, cutting ssDNA reporters to generate fluorescence signals. HOLMES(NAD+) shows both sensitivity and specificity in NAD+ detection and can be used for quantitative determination of intracellular NAD+ concentrations. Therefore, HOLMES(NAD+) not only provides a convenient and rapid approach for target NAD+ quantitation but also expands the application scenarios of HOLMES to non-nucleic acid detection. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 通讯
|
WOS研究方向 | Biotechnology & Applied Microbiology
; Engineering
|
WOS类目 | Biotechnology & Applied Microbiology
; Engineering, Biomedical
|
WOS记录号 | WOS:001198054700001
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:1
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/788720 |
专题 | 南方科技大学第二附属医院 南方科技大学第一附属医院 |
作者单位 | 1.Shenzhen Univ, Sch Biomed Engn, Guangdong Key Lab Biomed Measurements & Ultrasound, Natl Reg Key Technol Engn Lab Med Ultrasound,Med S, Shenzhen, Peoples R China 2.Shenzhen Univ, Shenzhen Peoples Hosp 2, Shenzhen Inst Translat Med, Dept Clin Lab,Affiliated Hosp 1, Shenzhen, Peoples R China 3.Shenzhen Bao An Peoples Hosp, Shenzhen, Peoples R China 4.Southern Univ Sci & Technol, Shenzhen Peoples Hosp 3, Affiliated Hosp 2, Natl Clin Res Ctr Infect Dis,Dept Clin Lab, Shenzhen, Peoples R China 5.Fudan Univ, Huashan Hosp, Inst Antibiot, Shanghai, Peoples R China 6.Natl Hlth Commiss, Key Lab Clin Pharmacol Antibiot, Shanghai, Peoples R China 7.Shanghai Tolo Biotechnol Co Ltd, Shanghai, Peoples R China |
通讯作者单位 | 南方科技大学第二附属医院; 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
Zhuang, Songkuan,Hu, Tianshuai,Zhou, Hongzhong,et al. CRISPR-HOLMES-based NAD+ detection[J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY,2024,12.
|
APA |
Zhuang, Songkuan.,Hu, Tianshuai.,Zhou, Hongzhong.,He, Shiping.,Li, Jie.,...&Wang, Jin.(2024).CRISPR-HOLMES-based NAD+ detection.FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY,12.
|
MLA |
Zhuang, Songkuan,et al."CRISPR-HOLMES-based NAD+ detection".FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY 12(2024).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论