题名 | Highly Sensitive Strain and Temperature Sensors Based on Vernier Effect in Cascaded Mach-Zehnder Interferometer and Sagnac Interferometer |
作者 | |
通讯作者 | Chen, Hailiang |
发表日期 | 2024
|
DOI | |
发表期刊 | |
ISSN | 0018-9456
|
EISSN | 1557-9662
|
卷号 | 73 |
摘要 | In this article, vernier effect (VE), which is an effective method to enhance the measurement sensitivity of strain and temperature, was experimentally studied through cascading a Mach-Zehnder interferometer (MZI) with a Sagnac interferometer (SI). The MZI consisted of a tapered single-mode fiber (SMF), while the SI was formed using a panda-shaped polarization-maintained fiber (PMF). Free spectral ranges (FSRs) of the two interferometers were slightly different from each other, and as a result, the VE was successfully excited. The experimental results demonstrated that the measurement sensitivity of strain was improved from 26.7 to -110.92 pm/mu epsilon at the temperature of 24 degrees C, while the measurement sensitivity of temperature was improved from -2978 to 7934 pm/degrees C at the strain of 0 epsilon. The sensitivity was amplified about four times. The cross-sensitivity of temperature and strain measurements is 71.53 mu epsilon/degrees C. The proposed sensor exhibits in advantages of simple in construction, high sensitivity, and multiparameter measurements making it a superior contender for strain and temperature monitoring in engineering |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 其他
|
资助项目 | Natural Science Foundation of Hebei Province, China[F2021203112]
; National Natural Science Foundation of China[12074331]
; Yangtze Optical Fibre and Cable Joint Stock Ltd. Company[x2022084]
|
WOS研究方向 | Engineering
; Instruments & Instrumentation
|
WOS类目 | Engineering, Electrical & Electronic
; Instruments & Instrumentation
|
WOS记录号 | WOS:001276438700001
|
出版者 | |
ESI学科分类 | ENGINEERING
|
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:1
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/790085 |
专题 | 工学院_电子与电气工程系 |
作者单位 | 1.Yanshan Univ, Sch Sci, State Key Lab Metastable Mat Sci & Technol, Qinhuangdao 066004, Peoples R China 2.Yanshan Univ, Key Lab Microstruct Mat Phys Hebei Prov, Qinhuangdao 066004, Peoples R China 3.Yanshan Univ, Coll Informat Sci & Engn, Qinhuangdao 066004, Hebei, Peoples R China 4.Southern Univ Sci & Technol, Dept Elect & Elect Engn, Shenzhen 518055, Peoples R China |
推荐引用方式 GB/T 7714 |
Shi, Ruyue,Chen, Hailiang,Fan, Xiaoya,et al. Highly Sensitive Strain and Temperature Sensors Based on Vernier Effect in Cascaded Mach-Zehnder Interferometer and Sagnac Interferometer[J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT,2024,73.
|
APA |
Shi, Ruyue.,Chen, Hailiang.,Fan, Xiaoya.,Liu, Chaoyi.,Li, Hongwei.,...&Li, Shuguang.(2024).Highly Sensitive Strain and Temperature Sensors Based on Vernier Effect in Cascaded Mach-Zehnder Interferometer and Sagnac Interferometer.IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT,73.
|
MLA |
Shi, Ruyue,et al."Highly Sensitive Strain and Temperature Sensors Based on Vernier Effect in Cascaded Mach-Zehnder Interferometer and Sagnac Interferometer".IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 73(2024).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。