中文版 | English
题名

Centrifugated lateral flow assay strips based on dual-emission carbon dots modified with europium ions for ratiometric determination and on-site discrimination of tetracyclines in environment

作者
通讯作者Chen,Da
发表日期
2024-11-15
DOI
发表期刊
ISSN
0048-9697
EISSN
1879-1026
卷号951
摘要
Due to the serious detrimental impact on human health, antibiotic pollution particularly tetracyclines residues has become a serious problem. Herein, a multiple response fluorescent probe consisted of dual-emission carbon dots and Eu (D-CDs@Eu) is designed for the determination and discrimination of tetracyclines (TCs). Specifically, the carboxyl and amidogen group of dual-emission carbon dots (D-CDs) can coordinate with Eu to form the D-CDs@Eu. Upon adding TCs, the fluorescence intensities of D-CDs at 405 nm and 495 nm are quenched due to inner filter effect (IFE) and the localization of fluorescence resonance energy transfer (L-FRET) between the D-CDs@Eu and TC. Simultaneously, the D-CDs@Eu may chelate with TCs to enhance the occurrence of antenna effect, while the characteristic peaks of Eu at 590 nm and 615 nm are enhanced. On these bases, the TCs detection is achieved with low detection limits from 46.7 to 72.0 nM. Additionally, through the distinct efficiencies of L-FRET, the discrimination of TCs is achieved. Moreover, a novel centrifugated lateral flow assay strips (CLFASs) device is developed by integrating the D-CDs@Eu, lateral flow assay strips and smartphone using RGB variations for TCs detection, achieving remarkable recoveries (98.6–103.7 %) in real samples. Therefore, this CLFASs device provides a reliable approach for the TCs detection, demonstrating potential applications.
关键词
相关链接[Scopus记录]
语种
英语
学校署名
其他
ESI学科分类
ENVIRONMENT/ECOLOGY
Scopus记录号
2-s2.0-85201198312
来源库
Scopus
引用统计
成果类型期刊论文
条目标识符http://sustech.caswiz.com/handle/2SGJ60CL/828581
专题工学院_材料科学与工程系
作者单位
1.Department of Microelectronic Science and Engineering,School of Physical Science and Technology,Ningbo University,Ningbo,315211,China
2.Department of Materials Science and Engineering,Shenzhen Key Laboratory of Full Spectral Solar Electricity Generation (FSSEG),Southern University of Science and Technology,Shenzhen,518055,China
3.Department of Chemical Engineering,Ningbo Polytechnic,Ningbo,315800,China
推荐引用方式
GB/T 7714
Hu,Houwen,Xing,Haoming,Zhang,Yihao,et al. Centrifugated lateral flow assay strips based on dual-emission carbon dots modified with europium ions for ratiometric determination and on-site discrimination of tetracyclines in environment[J]. Science of the Total Environment,2024,951.
APA
Hu,Houwen.,Xing,Haoming.,Zhang,Yihao.,Liu,Xinru.,Gao,Sineng.,...&Chen,Da.(2024).Centrifugated lateral flow assay strips based on dual-emission carbon dots modified with europium ions for ratiometric determination and on-site discrimination of tetracyclines in environment.Science of the Total Environment,951.
MLA
Hu,Houwen,et al."Centrifugated lateral flow assay strips based on dual-emission carbon dots modified with europium ions for ratiometric determination and on-site discrimination of tetracyclines in environment".Science of the Total Environment 951(2024).
条目包含的文件
条目无相关文件。
个性服务
原文链接
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
导出为Excel格式
导出为Csv格式
Altmetrics Score
谷歌学术
谷歌学术中相似的文章
[Hu,Houwen]的文章
[Xing,Haoming]的文章
[Zhang,Yihao]的文章
百度学术
百度学术中相似的文章
[Hu,Houwen]的文章
[Xing,Haoming]的文章
[Zhang,Yihao]的文章
必应学术
必应学术中相似的文章
[Hu,Houwen]的文章
[Xing,Haoming]的文章
[Zhang,Yihao]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
[发表评论/异议/意见]
暂无评论

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。