题名 | A microfluidic-based chemiluminescence biosensor for sensitive multiplex detection of exosomal microRNAs based on hybridization chain reaction |
作者 | |
通讯作者 | Hu, Hong; Gao, Dan |
发表日期 | 2025
|
DOI | |
发表期刊 | |
ISSN | 0039-9140
|
EISSN | 1873-3573
|
卷号 | 281 |
摘要 | The analysis of microRNAs (miRNAs) in exosomes is of great importance for noninvasive early disease diagnosis. However, current techniques to detect exosomal miRNAs is hampered either by laborious exosome isolation or low abundance of miRNAs in exosomes. Here, we developed a microfluidic chemiluminescence (CL) analysis method for the multiplexed detection of exosomal miR-21 and miR-155. The microfluidic device contained three parts: a snake-shaped channel for fully mixing chemiluminescent reagents, a ship-shaped channel modified with CD63 protein aptamer for capturing exosomes, and another two parallel ship-shaped channels for hybridization chain reaction (HCR) amplification and CL detection. The multiple signal amplification was realized by Y-shaped arrays, HCR amplification, and poly-HRP catalyzed CL reaction. Using this multiple signal amplification method, our microfluidic CL biosensor achieves a limit of detection of miRNAs of 0.49 fM, with a linear range of 1 fM-10 pM, which is better or comparable to previously reported biosensors. What's more, the proposed microfluidic biosensor exhibits great specificity and selectivity to the target miRNA. Moreover, the microfluidic CL strategy exhibited excellent accuracy and could significantly distinguish different cancer subtypes as well as cancer patients and healthy people. These results suggest that this simple, high sensitive, and more accurate analytical strategy by analyzing different types of exosomal miRNAs has the potential applications in cancer diagnosis and stage monitoring. |
关键词 | |
相关链接 | [来源记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 通讯
|
资助项目 | Natural Science Foundation of Guangdong Province, China[2022A1515011437]
; Shenzhen Fundamental Research and Discipline Layout Project[JCYJ20180508152244835]
|
WOS研究方向 | Chemistry
|
WOS类目 | Chemistry, Analytical
|
WOS记录号 | WOS:001314193800001
|
出版者 | |
来源库 | Web of Science
|
引用统计 |
被引频次[WOS]:7
|
成果类型 | 期刊论文 |
条目标识符 | http://sustech.caswiz.com/handle/2SGJ60CL/834251 |
专题 | 南方科技大学第一附属医院 |
作者单位 | 1.Tsinghua Univ, Tsinghua Shenzhen Int Grad Sch, State Key Lab Chem Oncogen, Key Lab Chem Biol, Shenzhen 518055, Peoples R China 2.Tsinghua Univ, Grad Sch Shenzhen, Key Lab Metabol Shenzhen, Shenzhen 518055, Peoples R China 3.Southern Univ Sci & Technol, Jinan Univ, Shenzhen Peoples Hosp, Affiliated Hosp 1, Shenzhen 518020, Guangdong, Peoples R China 4.Tsinghua Univ, Sch Pharmaceut Sci, Beijing 100084, Peoples R China |
通讯作者单位 | 南方科技大学第一附属医院 |
推荐引用方式 GB/T 7714 |
Peng, Jie,Li, Baicheng,Ma, Zhiyuan,et al. A microfluidic-based chemiluminescence biosensor for sensitive multiplex detection of exosomal microRNAs based on hybridization chain reaction[J]. TALANTA,2025,281.
|
APA |
Peng, Jie.,Li, Baicheng.,Ma, Zhiyuan.,Qiu, Zhengxuan.,Hu, Hong.,...&Gao, Dan.(2025).A microfluidic-based chemiluminescence biosensor for sensitive multiplex detection of exosomal microRNAs based on hybridization chain reaction.TALANTA,281.
|
MLA |
Peng, Jie,et al."A microfluidic-based chemiluminescence biosensor for sensitive multiplex detection of exosomal microRNAs based on hybridization chain reaction".TALANTA 281(2025).
|
条目包含的文件 | 条目无相关文件。 |
|
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论